electrical connection
A
Remove the central screw and lift the electrical plant box.
B
Remove the 3 fixed screws. Then position the electrical box so it is in line with the holes
of the previously removed screws and tighten.
C
Pay attention that the tear tape of the electrical box is inside the slot and then tighten screw.
A
C
1. Route the power cord to the junction box.
D
2. Using listed conduit fittings and connectors, connect the power supply to the box and
each line to the appropriate wire following this color convention:
BLACK = HOT LEG
WHITE = NEUTRAL
GREEN/YELLOW = GROUND
Polarity must be observed.
Unit must be properly grounded.
Use a double throw disconnect switch.
3. Replace the box cover
Replace the Anti-grease flters.
All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999