LED lighting and fan

The LED on the front of the unit will light up to illuminate the object when you press the
button. The fan will then run to cool the system. The fan will remain active throughout
the heating process and also thereafter if the measured internal temperature is high.
Once the temperature has returned to a normal level the fan will switch off automatically.
For this reason the 230 Volt mains connection should be maintained until the fan stops
running. The iDuctor will switch off (or fail to switch on) if a fault is detected. In that case
the LED light will flash when the button is depressed. (See: "Error messages".)
In order to prevent damage the iDuctor and the coil must be allowed to cool
thoroughly after use before they are returned to their storage box. Both the
unit and the coils can become hot in use.

Rotary switch and push button

The patented rotary switch at the rear of
the iDuctor is used to adjust the heating
time and power. These adjustments should
be made before you press the push button
on top of the unit to activate heating.
The settings can not be adjusted during
heating. Once adjustment is complete
the coil is held around the object to be
heated and the button on top of the unit is
depressed. In positions 1 to 5 the unit will
switch off automatically after the specified
time. In position 6 the unit will continue
to heat until the button is released or the
iDuctor is switched off by the internal
temperature safety cut-out. Once the
iDuctor has cooled sufficiently the heating
process will start up again automatically
when you press the button. The iDuctor 1
is active when the LED on the front is
illuminated.