Télécharger Imprimer la page

Thermor Riva 3 Notice D'installation Et D'utilisation page 22

Radiateur sèche-serviettes de 500 à 1000 w avec ou sans soufflerie (1000 w)
Masquer les pouces Voir aussi pour Riva 3:

Publicité

Les langues disponibles

Les langues disponibles

Where to install your device?
-
This equipment was designed to be installed in a residence. Please ask
your distributor before using it for any other purpose.
-
The device should be installed according to normal trade practice and
incompliance with legislation in the relevant country (NFC 15-100 for
France).
-
The equipment is class 2 and is protected against splashed water IP 24.
The device can be installed in volume 2 of a bathroom It's forbidden
to install the device in the volume 1. The device is to be installed so
that switches and other controls cannot be touched by a person in
the bath or shower.
Do not install the device :
-
In a draught that might affect adjustment (for example, under a central
mechanical ventilation unit etc...).
-
Under a fixed power socket or near curtains or other combustible
materials.
Locate the device within minimum
distances from obstacles.
Do not install shelf above the device.
The bottom case must be at least 5
mm from the wall.
In order to avoid a hazard for very
young children, this device should be
installed so that the lowest heated rail
is at least 600 mm above the floor.
Installation
INSTALLING THE DEVICE
Volume 1
Volume 2
No electrical device
Electrical device IPX4 .
(Standard EN 60335-2-
43 : 2003/A2: 2008)
250 mini
20
150 mini
250 mini
200 mini

Publicité

loading