REMOVAL OF FRONT GRILLE
Remove the front intake grille.
1
Pull up the front intake grille
about 90° and slide it slightly
to the left to unhook the tabs.
Do not raise the front intake grille any higher than
CAUTION
90° to the unit or damage to the tabs may occur.
Remove the front grille.
3
a a a a a
At bottom right side of the front grille, press inward on cabinet near the power cord, and pull
b b b b b
the grille outward to the right until right tab releases.
At the bottom left side, push inward on cabinet and pull the grille outward to the left to release
the left tab.
Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
c c c c c
damage.
Slide the front grille upwards to free the two top tabs from slots at the top of the cabinet.
HOW TO ATTACH THE DRAIN PAN (OPTIONAL)
Condensed water drainage
This air conditioner employs a "Slinger-Up System" which is designed to splash the condensed
water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
If the splashing sound annoys you, you can provide an outside drainage by using the following
procedure which may, however, cause a small loss of performance.
Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
drainage. (Max. 13/32")
Remove the rubber plug and slide the chassis out from
1
the cabinet.
Install the optional drain pan (part no. CWH40175).
2
Install the drain pan at the right
corner of the cabinet using 2
screws (part no. CWG86C733).
Note
The
drain
CWH40175) can be obtained
from nearest servicentre.
MAIN UNIT
3
4
5
8 Ventilation lever
The ventilation lever must be in the CLOSE position in order to
maintain the best cooling conditions. When fresh air is necessary
in the room, set the ventilation lever to the OPEN position. The
damper is opened and room air is drawn out.
TYPES OF SIGNAL SOUND
One long "Beep" and one short "Beep". (Sound from the main unit.)
All manuals and user guides at all-guides.com
Remove the
rubber plug
INTERNAL VIEW
Screws
pan
(part
no.
Drain pan (optional)
1 Air inlet louvre
1
2
2 Cabinet
6
7
3 Power cord
7 Vertical airflow direction vane
8
(Airflow direction adjustment up-
down).
The vertical airflow direction vane
9
3
is controlled by rotating the
horizontal vane forward or backward.
Remove the air filter.
2
Tilt up and pull out
Air filter
the air filter by the
holder.
Connect a drain hose (optional).
3
Fit the drain hose to the drain pan.
Note
Drain hose or tubing can be
purchased locally to satisfy your
particular needs.
Slide the chassis back into the
4
cabinet.
Reinstall the cabinet screws.
Secure the cabinet to chassis by
using screws.
4 Air filter (behind the
9 Touch control panel
front intake grille)
5 Front intake
grille
6 Front grille
a Display Panel
b MODE selection pad
c FAN SPEED selection pad
d TEMPERATURE/TIMER
e TIMER pad
g OPERATION OFF/ON pad
h AIR SWING pad
c c c c c
b b b b b
a a a a a
Maximum
13/32"
Condensed water
EXTERNAL VIEW
Drain hose
(not included)
Underside view with drain
pan and hose in place.
e
d
OPERATION
TIMER
a
TEMP/TIMER
SET
OFF/ON
hr
SET/
g
f
CANCEL
COOL
b
JET
MODE
AIR SWING
MODE
FAN
i
h
HIGH
Wireless
c
FAN SPEED
R e m o t e C o n t r o l
LOW
setting pad
f Timer SET/CANCEL pad
i JET MODE pad

Publicité

loading

Ce manuel est également adapté pour:

Cw-xc120vk