Télécharger Imprimer la page

Air Naturel Pump It Up Notice D'utilisation page 9

Mini pompe de relevage pour déshumidificateur d'air

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Pump It Up water-pump correctly installed
Air dehumidifier
fitted with
continuous
drainage function
Water tank
Pump
Troubleshooting
Problem
The pump doesn't start
The pump doesn't evacuate
water
The pump doesn't stop
Water extraction capacity
is weak
Possible cause
The pump is not plugged in
Filter (5) might be
obstructed or dirty
The pipe (4) might be
obstructed or kinked.
Water sensor (6) has an
electronic contact failure
Filter (5) might be
obstructed or dirty
Watertank water is dirty
To water
outlet
Drain
pipe
Pipe and electrical
cable outlet
male and
female
Power supply
electrical
junction
Solution
Check the voltage input/
output
Clean the filter (5) with clear
water and gentle soap.
Rinse well.
Unbend the pipe to ensure
water is not impeded (4)
Unplug and remove the
pump. Dry and then clean
the water sensor (6) with a
dry duster
Clean the filter (5) with clear
water and gentle soap.
Rinse well.
Clean the pump and
watertank with clear water
and gentle soap. Rinse well.
9

Publicité

loading