4.3 MANUAL CLEARING THE RECEIVER
MEMORY/RECEIVER RESET
DESCRIPTION
Press the button on the receiver and hold it down until the
LED lights up (about 3 seconds) and then goes out (about 3
seconds). Release the button
About 1 second after the button is released, the LED on the
receiver starts to flash
To clear the entire memory, press the receiver button on the
third flash, or to reset the 4 outputs and restore the default
monostable settings, press the button on the fifth flash
If the deletion/reset has been successful, the receiver will give
one long flash
4.4 MANUAL REMOTE MEMORISATION OF A REMOTE
CONTROL WITH A REMOTE CONTROL ALREADY
MEMORISED
A transmitter can be memorised without accessing the receiver. The user needs to have a transmitter
memorised previously, after which the procedure is as described below. The remote copy procedure
must be carried out in the area served by the receiver.
DESCRIPTION
Press the button of the new remote control to be memorised,
holding it down for at least 5 seconds
Press the button of the old remote control to be copied (if phase
1 has been successful, the automation system will not respond)
Press the button of the new remote control to be memorised,
holding it down for at least 3 seconds
Press the button of the old remote control to be copied,
holding it down for at least 3 seconds, to confirm and quit the
programming mode
If no commands are given for 7 seconds, the receiver
automatically quits the programming mode
5 - TESTING AND COMMISSIONING
The system may be put into operation after testing by a qualified technician, who must perform the
tests required by the relevant standards in relation to the risks present, to check that the installation