In order to guarantee correct and s afe functioning of the s ystem, the same must be s upplied with the following devic es:
4
8
9
1
Once the connec tions to the unit ar e made, c hec k that none of the pipes leak, and bleed the air from the s ystem.
II.2.7.2
Condenser hydraulic connection
IMPORTANT !
The layout of the water system and connection of
the system to the unit must b e carried out in
conformity with local and national rules in force.
IMPORTANT !
For correct functioning of the unit, a flo w r ate to the
recover y units must b e guar anteed that is at least
equal to the nomin al flo w r ate stated in the t able of
the Attachm ents.
The pi ping must be mec hanicall y isolated and s upported in a way to
prevent anomal ous str ess on the unit.
The di mensions of the condens er connec tions are given in the
attac hments of this manual. In or der to guarantee correct and s afe
IN
MODEL
Dimensions
j
Condenser water input
Condenser water output
MODEL
Dimensions
j
o
Condenser water input
Condenser water output
MODEL
Dimensions
j
o
Condenser water input
Condenser water output
MODEL
Dimensions
j
m
n
Condenser water input
Condenser water output
6
6
4
5
7
3
1
2
mm
GF
GF
mm
mm
GF
GF
mm
mm
GF
GF
mm
mm
mm
GF
GF
5
functi oning of the s ystem, the s ame must be supplied with the following
devices:
• air bleed val ves and c ut-off val ves must be mounted on the infeed
and outfeed pipes from the unit in or der to isolate the machine from
the res t of the s ystem and this allow the heat exchanger to be
emptied and/or any maintenanc e or removal of the same.
• A filter must be mounted on the c ondenser input piping and anti-
vibration j oints i n correspondence of the hydraulic fitti ngs.
Once the connec tions to the unit ar e made, c hec k that none of the
pipes l eak, and bl eed the air from the s ystem.
1201-1611
j
OUT
1201
1231
1281
1311
293
293
293
293
5"
5"
5"
5"
5"
5"
5"
5"
2411
2431
2461
2511
293
293
293
293
650
650
650
650
5"
5"
5"
5"
5"
5"
5"
5"
2781
2841
2901
2961
293
293
293
293
650
650
650
650
5"
5"
5"
5"
5"
5"
31301
31351
31401
294
294
294
360
360
360
360
360
360
5"
5"
5"
5"
5"
5"
65
SECTION II: INST ALL ATION AND MAINTEN ANCE
IN=Water input
OUT=Water output
1.
Shut- off valve;
2.
Drain;
3.
Filter(0.5 mm square mes h);
4.
Thermometer;
5.
Anti-vi bration dilation j oint;
6.
Manometer;
7.
Flow s witch;
8.
Regulation val ve;
9.
Air vent.
2411-21261
j
o
1351
1421
1481
1531
293
293
293
293
5"
5"
5"
5"
5"
5"
5"
5"
2561
2601
2631
2681
293
293
293
293
650
650
650
650
5"
5"
5"
5"
5"
5"
5"
5"
21031
21111
21181
293
293
293
650
650
650
5"
5"
5"
5"
5"
5"
5"
5"
31461
31521
31591
294
294
294
360
360
360
360
360
360
5"
5"
5"
5"
5"
5"
31301-31631
j
m
n
1611
293
5"
5"
2711
293
650
5"
5"
21261
293
650
5"
5"
31631
294
360
360
5"
5"

Publicité

Table des Matières
loading

Table des Matières