NECESSARY MATERIALS
1 crosshead and a flat screwdriver.
1 drill with 6 mm Ø masonry bit.
The 6 batteries (supplied).
The fixing accessories supplied.
2 antenna end caps (supplied), 2 antenna tubes (supplied).
INSTALLATION
Caution: The tamper protection for the removal, the opening of the housing and
the cutting of the antennas is inactive at the time of installation of the siren. It
becomes active after the first arming command (partial or total) is received and if the
tamper actuator is engaged for more than 5 sec. It is strongly advised to wait until
the siren is fixed to the wall before sending any arming commands.
FIG. A
Front view of the alarm siren
Strobe (SA210 siren).
Sounder.
FIG. B
Opening
Unscrew the 3 screws from the rear of the housing, turn the siren over.
1
Remove the lid, you have access to the internal housing.
2
Insert your screwdriver in the place indicated by an arrow between the 2 anten-
3
nas to unclip the battery compartment lid.
Remove the battery compartment lid.
4
FIG. C
Guarantee Label
Remove the detachable half of the guarantee label and affix it to the guarantee
extension request form supplied with the control panel's documentation.
In the event of this being an addition to a system: Affix the Label to the guarantee
extension request supplied with the product and send it to the address indicated on
documents supplied.
FIG. D
Setting up the antennas
In the sirens packaging you will find the two antenna tubes.
Place the antenna caps on the ends of the tubes.
1
Slip the antenna wires completely into their corresponding tubes.
2
Slot the tubes into the vertical channels using your flat screwdriver to lock them in
3
place.
GB
All manuals and user guides at all-guides.com
24
FIG. E
Modes of operation
Select the modes of operation via the 4 selection switches:
Position
of the
Siren operation
microswitches
Siren (and strobe)
duration 20 sec
Siren (and strobe)
duration 40 sec
Siren (and strobe)
duration 90 sec )
Siren duration 1 min
30 sec.
Strobe duration 15
min
(1) The sirens audible message report is a repeat of the audible messages from the
control panel at the time of arming and disarming. It only functions when the control
panel is in normal mode (fixed to the wall). However, the audible message report is
active during the installation of the siren.
Note the chosen options on the memo page of your
FIG. F
Installing the batteries
Carefully take the battery connector and connect the 6 supplied batteries. Refit it in
its housing as indicated.
Carry out the personalised radio code learning as described in the following section.
FIG. G
Personalised radio code learning
The learning of the personalised radio code to the siren is carried out from a remote
control or a keypad whose radio code has been previously programmed.
This learning must be achieved when the control panel is in test mode, that is to say
not fixed to the wall.
Position
of the
Siren operation
microswitches
Control panel
audible signals not
reported (1)
Control panel
audible signals
reported (1)
Shrill alarm sound
(for interior use)
Alarm sound audible
at long distance (for
exterior use)
DIAGRAL
user guide.
GB
25

Publicité