Télécharger Imprimer la page

Important - BFT CLONIX UNI AC U-LINK 230 Instructions D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
TABLE "C" - LOGIC MENU - (logic)
Logic
Definition
Fixed code
FIXED CODE
Setting the
Protection
protection
level
level
Address
ADDRESS
TABLE "D" SLOTS CONFIGURATION MENU (conf. s lots)
SLOT PARAM.
Definition
Slot input
address
operation type
type
configuration
Remote
Command
remote ID
address
Open
Command re-
open
mapping
Start
Command re-
start
mapping
Stop
Command re-
stop
mapping
Pedestrian
command re-
ped
mapping
INSTALLATION MANUAL
Cross out
Default
setting
used
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmit-
0
ters by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added
to the receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
0
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0
logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops
radio interference, if any.
Identifies board address from 0 to 119 in a local BFT network connection.
0
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
Cross out
Default
setting used
The command received on this slot is sent to the other two u-link slots, keeping the target address constant, if
there is a B EBA U-LINK 485 board on it, the command is sent to downstream devices and resolved if the right
0
address is found.
Each command received on this slot is locally run thus on Clonix U-Link
0
1
Each command received on this slot is re-routed to the address indicated in the remote ID field. This command is
sent to the other two u-link slots, if there is a B EBA U-LINK 485 board on it, the command is sent to downstream
2
devices and resolved if the right address is found.
[ ___ ]
Address of the board where the command is re-routed. Only taken into account if the Address type setting is 2.
0
The Open command received via U-LINK protocol does not activate any output
0
The Open command received via U-LINK protocol activates output OUT 1
1
1
The Open command received via U-LINK protocol activates output OUT 2
2
The Open command received via U-LINK protocol activates output OUT 3*
3 *
The Start command received via U-LINK protocol does not activate any output
0
The Start command received via U-LINK protocol activates output OUT 1
1
1
The Start command received via U-LINK protocol activates output OUT 2
2
3 *
The Start command received via U-LINK protocol activates output OUT 3*
The Stop command received via U-LINK protocol does not activate any output
0
The Stop command received via U-LINK protocol activates output OUT 1
1
2, 3 *
The Stop command received via U-LINK protocol activates output OUT 2
2
The Stop command received via U-LINK protocol activates output OUT 3*
3 *
The Pedestrian command received via U-LINK protocol does not activate any output
0
The Pedestrian command received via U-LINK protocol activates output OUT 1
1
1
The Pedestrian command received via U-LINK protocol activates output OUT 2
2
The Pedestrian command received via U-LINK protocol activates output OUT 3*
3 *
Optional extras
Description
17
CLONIX U-LINK

Publicité

loading

Ce manuel est également adapté pour:

Clonix 2e ac u-link 230