Program Interval Control - Hobby Biotherm Pro Mode D'emploi

Masquer les pouces Voir aussi pour Biotherm Pro:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50

5.4.3 Program interval control

Indicator "00:" is flashing.
To adjust interval ON Time,
use the ▲ and ▼ buttons to set the hours between 0 and 23.
button, the minutes digits "00" will flash.
Press the
Use the ▲ and ▼ buttons to set the minutes between 0 and 59.
button, the seconds will flash - "00".
Press the
Use the ▲ and ▼ buttons to set the seconds between 0 and 59.
Press
.
Indicator "00:" is flashing.
To adjust interval OFF Time,
use the ▲ and ▼ buttons to set the hours between 0 and 23.
Press the
button, the minutes will flash - "30".
Use the ▲ and ▼ buttons to set the minutes between 30 and 59*.
Press
.
If you want to finish programming, press and hold
* Settings between 0 and 59 are only possible with intervals of 1 hour or longer. For shorter intervals, a minimum of
30 minutes is preset by the manufacturer to protect electronic components.
Note: The first interval control is triggered immediately after the system returns to operating mode.
6. Werksvoreinstellung / Reset
Clock setting:
Temperature 1:
Temperature 2:
Audible temperature 1 alarm:
Visual temperature 1 alarm:
Audible temperature 2 alarm:
Visual temperature 2 alarm:
Temperature mode:
Timer mode:
14
All manuals and user guides at all-guides.com
for 3 seconds until the display returns to operating mode.
12:00:00
25° C
25° C
deactivated (Beep off)
deactivated (00 means no alarm)
deactivated (Beep off)
deactivated (00 means no alarm)
Heating
Aut (means 'automatic')