Troubleshooting - AEG MB 1.0 Mode D'emploi

Pulseur de batterie à microprocesseur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

TROUBLESHOOTING

Error/Problem
red LED lights up
(longer than 3
seconds)
red LED doesn't
light up
Possible cause
Defective battery
Battery voltage below 15 V
The battery voltage is less than
11 V after 4 minutes
The battery voltage is less than
12 V after 2 minutes
The battery pulser was unable to
fully restore a charge within 86
hours
Terminal connection cable connec-
ted incorrectly
No power supply, battery pulser
not plugged in
Unplug the battery pulser and
check the connections
Defective battery
Battery voltage below 05 V
Low temperatures (below 0 ˚C)
Explosion hazard!
Never charge frozen
Correction
Replace battery
Replace battery
Unplug the battery
pulser and check the
connections
Verify the battery
pulser is plugged
into a 230 V power
outlet
Unplug the battery
pulser and check the
connections
Replace battery
Charge battery in
normal conditions
batteries
GB