Preparation - Urmet 1051 Manuel D'installation, De Programmation Et D'utilisation

Masquer les pouces Voir aussi pour 1051:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wired terminals
Terminal 1 is used as a roller shutter opening detector.
Terminal 2 is used for connection to any device with NC contact (normally closed). The signalling of an alarm on this input
will be of the same type as that indicated by the opening of the door.

Preparation

Remove the insulation of the battery.
Activate the learn function on the control unit.
By means of the learn function, pair the internal/tamper magnetic switch and the wired inputs to an input of the control unit.
-
Press the test button for the learning of the device.
If the signal is received from the control unit it will show the corresponding information. Refer to the control unit manual to
complete the learning procedure.
Once the contact learning procedure has been run, set the control unit to "Walk Test" mode, holding the contact in the
required position and press the Test button to confirm that the chosen position is within the radio range of the control unit.
Proceed with the installation after having ascertained that the contact is working in the desired position.
Mounting and installation methods
The contact must be positioned on the door frame while the magnet must be positioned on the door. If
the contact is positioned on the door and the door is opening too fast, the transmission distance may be
reduced.
The magnet must not be more than 15 mm from the contact when the door is closed.
<
N
O
T
E
>
<
N
O
T
E
>
If the contact cannot be installed on the door frame, additional opening detectors can be used
on the wired inputs (see the "How to use the terminals" section for details).
Step 1: Identify an appropriate position near the door/window where the contact is positioned.
Step 2: The contact has two rib-marks on one side which indicate the position of the magnet. The
contact may be installed straight or upside down to ensure that the rib-marks are aligned with
the magnet.
Step 3: To fit the contact:
(i)
(ii)
(iii)
Step 4: Position the magnet on the door using the two-sided adhesive or the screws provided. The magnet must be aligned
with the side rib-marks of the contact as shown in the
<
N
O
T
E
>
<
N
O
T
E
>
Make sure that the spring of the tamper switch makes contact against the resting surface passing through the opening
of the tamper switch.
Step 5: Test the contact by opening and closing door or window with the control unit in "Walk test" mode.
Step 6: Insert the white plugs in the two mounting holes of the contact.
Step 7: The installation is complete.
Jumper and internal terminals
1. Terminal block 1
Connect a shutter opening detector.
1. Terminal block 2
Connect any device with NC contact (Normally Closed).The signalling of an alarm on this input will be of the same
type as that indicated by the opening of the door.
3. Reserved jumper (JP2)
4. Door alarm enabled jumper (JP3)
This jumper can be used to enable/disable the alarm caused by opening the door.
If the jumper is ON (the jumper is inserted on the two pins), detection is deactivated and the roller and NC input
alarms remain enabled.
If the jumper is OFF (jumper removed or "arranged" on a pin), detection is enabled (default setting).
5. Roller open detector setting jumper - 5 pulses/off (JP4)
This jumper can be used to select how many pulses are needed to activate the roller opening alarm.
With the jumper set to ON, the alarm is generated when 5 pulses are counted in 10 seconds.
If the jumper is set to OFF, the alarm is not activated after 5 pulses in 10 seconds (default setting).
6. Roller open detector setting jumper - 6 pulses/off (JP5)
This jumper can be used to select how many pulses are needed to activate the roller opening alarm.
With the jumper set to ON, the alarm is generated when 6 pulses are counted in 10 seconds.
DS1051-012A
Using the two mounting holes of the contact as a template, mark the position of the holes in the more
suitable position.
Insert the anchor bolts if the device is fixed to plaster or bricks.
Screw the contact onto the anchor bolts.
figure.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1051/203

Table des Matières