Settings: Before installing the urinal (figure 7) the following operating conditions can be modified:
Flush volume - (figure 11.1) factory setting is 0.5 litres for a flow pressure of 4 bar.
Setting options 0.5 to 4 litres. Pressing the left button for 1 seconds increases the value to 4 litres.
The setting is displayed as a flashing sequence.
Hygiene flushing - (figure 11.2) factory setting is 24 hours
Prevents the siphon trap drying out. In the event of the urinal not being used for a long time, an
automatic flush is activated. The period to elapse can be 24 or 72 hours. Hygiene flushing can be
turned off.
Diagnostic function - (figure 11.3)
Using the diagnostic function, the battery condition or power supply status, sensors and solenoid
valve can be checked and user statistics displayed.