Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Spare parts

Care instructions for Flushcontrol 1000 (N)
Operating mode
Flushcontrol 1000 (N) has an external sensor (multi-parameter sensor) which is attached to the moulded suction
section. Flushing is activated when a use is detected. Thanks to these properties, the Flushcontrol 1000 (N) is a
reliable flushing system.
Operational test
A simple operational test is possible by adding 0.1 l saline solution (0.4%), warm water or direct contact with a
metallic object (screwdriver etc.) by immersing in the residual water.
Unsuccessful operational test?
If the operational test of the Flushcontrol 1000 (N) is unsuccessful in that flushing does not occur, this could be
due to urine scale deposits up to the wall connections.
Care instructions
To ensure the smooth operation of the urinals, regular cleaning and maintenance is necessary. Deposits (urine
scale) result from hard water and urine. These deposits can be reduced by cleaning. From time to time it is
necessary to change the moulded suction section.
Rinse stop for cleaning
By plunging a metallic object (not isolated) for about 15 seconds into the residual water, the cleaning session is
initiated. The object has to be touched with bare fingers in doing so. The start of the cleaning session is
acknowledged by two flush cycles with 0.5 l flush volume and 4 seconds interval between both cycles. For about
30 seconds the flushing system is not functional and there is no flushing initiated. At the end of the cleaning
session a flushing with about 2 l flush volume is carried out. From then on the flushing system returns to the
normal operation mode.
Course of action in the case of deposits If urine scale or other deposits have formed in the moulded suction
section or in the siphon trap bend, these must be removed either manually or with a recommended detergent
(Duck Power Total Clean or similar) depending on the degree of contamination. In doing so it is important that
the deposits in the siphon trap bend or in the junction to the drain pipe are also removed in order to prevent
rapid accumulation in the moulded suction section from the waste outlet. The moulded suction section must
either be cleaned or replaced depending on the degree of contamination.
Since the siphons are wear items, soilings of the siphons are not covered by the two-year warranty.
Recommended detergents:
Domestos Zero Limescale
http://www.domestos.co.uk
* This detergent is intended for the professional sector
info@hygiene-shop.eu - www.hygiene-shop.eu
Duck Power Total Clean
http://www.scjohnson.co.uk
12
Toilet cleaner Kiehl Powerfix-Gel*
http://www.kiehl-group.com