Attach Fittings to Water Line
Slip a compression nut onto each pipe.
1
Next, slip the brass ferrule onto each pipe.
2
Installing the Unit
Align filter assembly with pipe ends, making certain that the
1
incoming water supply is going into the filter opening marked
"IN" . It may be necessary to spread the pipe ends apart to
install filter assembly.
" wrench to hold the fitting in place; use a 1
Using a 1
1
2
8
wrench to tighten the nut. Repeat process for other fittings.
Installing the Ground Wire
NOTE: If your house plumbing is plastic, it would not be used as
a grounding path, and this step should be skipped.
IMPORTANT: A copper or galvanized cold water pipe is often used
to ground electrical outlets in the home. Grounding protects you
from electrical shock. The water filter housing may have broken
this ground path. To restore connection, install a 12"-long,
6-gauge copper wire across the filter, and tightly clamp using
UL-approved 1/2"–1" bronze grounding clamps at both ends as
shown. Zinc clamps should not be used on copper plumbing.
Wire and clamps may be purchased separately from your local
hardware store.
Final Check
Install filter, if not already done. (See Filter Cartridge
1
Replacement section.)
Slowly turn on water supply.
2
Check entire system for leaks.
3
Timer Installation and Application Instructions
Blue reset button
Timer cap
2 AAA
batteries
Timer base
Timer seat
Head
STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.)
1
Timer battery installation and change
Insert coin or screwdriver into the slot between
timer cap and base. Gently pry them open and
separate timer base from cap. Install or change
2 new AAA 1.5-volt batteries. After you have
the batteries in place, line up the base and cap
and snap them back together.
It is recommended to change the batteries at
least every 2 filter changes, or when the blue
LED light seems dim.
Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc.) batteries.
Hex nut
Hang mounting bracket with unit onto previously installed
3
screws. Drive two screws to secure unit tightly to the wall if
necessary.
Install a filter into the housing and tighten canister to seal
4
"
(see Filter Cartridge Replacement section).
4
Clean copper pipe and ends of wire with emery paper. Bare
1
wire is recommended. If insulated wire is used, it should be
stripped 3/4" at each end before cleaning with emery paper.
Attach bronze clamps to copper pipe. Tighten screws.
2
Attach wire to clamps as shown. Tighten screws.
3
If leaking from fittings, shut off water pressure and tighten or
4
reseal fittings. If leaking from the canister, tighten the canister
with a wrench.
Open any downstream faucet and allow filter and housing to
5
flush for 30 minutes (model GXWH20S) or 15 minutes
(model GXWH04F).
Installation of timer
Hold the timer body in the center and gently
push the timer to its seat at the top of the head
or attach it in a remote location for easy viewing.
Timer reset and application
After new batteries are installed or filter is
changed, push and hold the blue timer reset
button (hold the reset button for approximately
5 seconds). Release the reset button after the
light stops flashing. The timer has been reset.
The light will flash again in 90 days to remind
you that it is time to change the filter.
4
D
Brass ferrule
Brass ferrule
Hex nut
Ground wire
Clamp