Manuel d'applications
Application 6 Câblage:
PrimPump
Comb
CH
DHW
Fuel
Flow Proof
Air Proof
Call
Tank Call
Switch
1
2
3
4
5
6
7
8
9
Meets Class B: Canadian
ICES & FCC Part 15
Prim Pump Flow Proof / Off
Validation de débit de la pompe prim/OFF
Comb Air Proof / Off
Validation de la combustion d'air/OFF
Off / Exercise
OFF/Exercice
Setback / Off
Recul/OFF
47
48
49
50
51
52
Primary
Primary
Pump
Pump
Boiler 1 (Chaudière 1)
P1
P2
+
Mod
1
Prim Pump
Flow Proof
2
3
Comb Air
Proof
4
5
CH
Call
6
7
DHW Tank
Call
8
9
Fuel
Switch
10
11
20V dc Out
12
mA (+) In
13
5V dc Out
14
V dc (+) In
15
Gnd (-)
16
EMS (+)
17
Outdoor
18
Prim Sup
19
Com (-)
20
Prim Ret
21
DHW
22
Com
23
Com Flue
24
Boil In
25
Com
26
Boil 1 Out
27
Boil 2 Out
28
Com
29
Boil 3 Out
30
Boil 4 Out
31
Com
32
tN4
Bus b
Boiler
C0
33
34
Bus 1 tN4
35
Boiler
C1
36
Bus 2 tN4
Boiler
C2
37
38
Bus 3 tN4
39
Boiler
C3
40
B (+)
RS485
41
A (-)
42
Gnd
43
Auxiliary
44
Bosch Thermotechnology Corp.
20V
mA
5V
Vdc
Gnd
EMS
Out
Prim
Com
Prim
DHW
Com
Com
dc
(+)
dc
(+)
(-)
(+)
door
Sup
(-)
Ret
Flue
Out In Out
In
In
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Flow
Pressure
Capteurs de températures - N'applique pas la puissance
Temperature Sensors - Do Not Apply Power
Capteur
Capteur de
Sensor
Sensor
de débit
pression
53
54
55
56
57
58
59
60
61
62
63 64
65
Boiler 1
Boiler 2
Boiler 3
Boiler 2 (Chaudière 2)
Boiler 3 (Chaudière 3)
-
Stage 1
Stage 2
+
Mod
-
Stage 1
Stage 2
+
Mod
-
Stage 1
Combustion Air
Validation de
Proof
combustion d'air
Permanent
Appel permanent (bond)
Call (Jumper)
Outdoor
Capteur de extérieur (S1)
Sensor (S1)
Capteur d'approvisionnement
Primary Supply Sensor (S2)
primaire (S2)
Capteur de retour primaire (S3)
Primary Return Sensor (S3)
Capteur de DHW (S4)
DHW Sensor (S4)
Capteur de sortie de chaudière 1 (S6)
Boiler 1 Outlet Sensor (S6)
Capteur de sortie de chaudière 2 (S7)
Boiler 2 Outlet Sensor (S7)
Boiler 3 Outlet Sensor (S8)
Capteur de sortie de chaudière 3 (S8)
Boiler 4 Outlet Sensor (S9)
Capteur de sortie de chaudière 4 (S9)
B
Optional Modbus
Connexion BAS
®
A
Modbus
BAS Connection
®
optionnelle
G
R
C.A. Damper
Clapet C.A.
C
Boil
Com
Boil 1
Boil 2
Com
Boil 3
Boil 4
Com
tN4
C0
In
Out
Out
Out
Out
BACnet IP
Bus b
Boiler
24
25
26
27
28
29
30
31
32
33
tekmarNet Communication
Home
(Accueil)
Heatronic 4000
4 Contrôle de la chaudière, DHW, BACnet et Modbus
4 boiler control, DHW, BACnet and Modbus
66
67
68
69
70
71
72
73
74
75
76
Boiler 4
Boiler 1
Boiler 4 (Chaudière 4)
Stage 2
+
Mod
-
Stage 1
Stage 2
Pump
RJ45
45
Alert
Dry
46
47
Primary
Pump P1
48
49
Primary
Pump P2
50
51
Mod
52
53
Stage 1
54
55
Stage 2
56
57
Mod
58
59
Stage 1
60
61
Stage 2
62
63
Mod
64
65
Stage 1
66
67
Stage 2
68
69
Mod
70
71
Stage 1
72
73
Stage 2
74
75
Boiler 1
Pump
76
77
Boiler 2
Pump
78
79
Boiler 3
Pump
80
81
Boiler 4
Pump
82
83
Power
In
84
85
DHW
Tank Pump
86
Contrôle Heatronic 4000 de Bosch | 21
tN4
C1
tN4
C2
tN4
C3
B
A
Gnd
Bus 1
Bus 2
Bus 3
(+) (–)
Auxiliary
Boiler
Boiler
Boiler
RS485
34
35
36
37
38
39
40
41
42
43
tektra 1056-02
Input Power:
Puissance d'entrée:
115 V (ac) ±10%, 60 Hz, 18 VA
Primary Pump Relays:
Relais de pompe primaire:
230 V (ac), 10 A, 1/2 hp
OUTREPASSER
MANUAL
Boiler & DHW Pumps:
Pompe de chaudière et DHW:
230 V (ac), 5 A, 1/3 hp
LE MANUEL
OVERRIDE
Boiler Stage, Auxiliary &
Phase de chaudière,
Alert Relays:
auxiliaire et relais d'alerte:
230 V (ac), 5 A, 1/6 hp
Calls: 24 V (ac) or Short
Appels: 24 V (ac) ou court
158033
Type 1056-XX
Signal wiring must be
Le signal de câblage doit
rated at least 300 V.
WARNING! Before opening
être donné au moins à 300 V
AVERTISSEMENT! Avant
the cover disconnect from
d'ouvrir le couvercle,
Designed and
Conçu et assemblé
power supply
veuillez disconnecter de
assembled in Canada
au Canada par tekmar
l'alimentation.
by tekmar Control Systems
Control Sytems
77
78
79
80
81
82
Boiler 2
Boiler 3
Boiler 4
Power In
Pump
Pump
Pump
Optional BACnet
Connexion BAS BACnet
Connection
optionnelle
+
-
T
Stage 1
T
T
Stage 2
T
+
-
T
Stage 1
T
T
Stage 2
T
+
+
Mod
-
-
T
Stage 1
T
+
+
Mod
-
-
T
Stage 1
T
L
Pompe de chaudière 1 (P1)
Boiler 1 Pump (P1)
N
L
Pompe de chaudière 2 (P2)
Boiler 2 Pump (P2)
N
L
L
Approvisionnement de
115 V (ac) Power Supply
N
N
puissance 115 V (ca)
L
Indirect DHW Pump (P3)
Pompe indirecte DHW (P3)
N
Les données sont sujettes à changement
Alert
Dry
44
45
46
83
84
85
86
DHW
Tank
L
N
Pump
BAS
®
®
Two Stage
Chaudière
On / Off
ON/OFF à
Boiler
deux phases
Two Stage
Chaudière
On / Off
ON/OFF à
Boiler
deux phases
Modulating
Chaudière
Boiler
modulaire
Modulating
Chaudière
Boiler
modulaire