Except for the COR-F-1000 N RF, F-1500 N RF and F-2000 N RF, that can only be used as an Air Curtain with fresh air, the rest of models
on this range have the option of working either with fresh or warm air.
We advise you to check that the unit is in perfect condition when unpacking it, as any manufacturing or quality defect is covered
by the S&P guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or below a socket.
Do not cover the unit with clothes or objects that may obstruct the airfl ow and cause overheating.
While in operation, the connection cable must not be in front of the air outlet.
If it is installed in the bathroom, it must be placed so that the switches or other devices of command cannot be touched for a person
that be in the bathtub or shower.
There must not be any infl ammable objects at less than 50 cm from the unit (such as window curtains, etc.). Keep the inlet and
outlet grilles clean. When cleaning them, disconnect the unit from the main supply. Do not manipulate the unit with wet hands.
The installation work must be carried out by an electrician.
IMPORTANT: THIS APPLIANCE MUST BE EARTHED.
The means of disconnection from the mains supply must have an opening distance of at least 3 mm in all poles.
To operate the unit as an Air Curtain, the maximum distance to the fl oor must not be greater than 3 m.
The minimum distance between the Air Curtain and the fl oor must be 1,8 m.
INSTALLATION
The unit must be fi xed to a convenient surface, and the minimum distances shown on Fig. 1 must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device are used, there must be marked the centers of the screws (M-8) according to the table
of Fig.2 (a) and Fig.2 (b). If the hanging fi xation is used, the centers must be marked according to the table of Fig.3 (a) and Fig.3 (b) and
place the screws (D) and the set squares (E). Then hang the device and to fi x on the lowest part with the screw (G).
When the included wall bracket kit is used Fig. 4 (2 pcs. for 1000 models and 3 pcs. for 1500/2000 models) set the support (L) to
the back part of the curtain with the screws provided (I). Fix the brackets (J) to the wall to match with the brackets on the curtain
(L). See dimensions Fig. 3 (a) and Fig 3 (b). Then hang the device and fi x on the lowest part with the screw (K).
ELECTRICAL CONNECTION (Fig. 5)
The COR Air Curtains are installed appliances. When installing these air curtains, the standards and regulations in force in your
country must be followed strictly adhered to. Within the installation an electrical isolation switch must be present, to enable the
installer to cut all supply lines.
Connect the unit to the mains supply, checking that the voltage and frequency are the same as those indicated on the electrical
rating plate. Use the cables with the number of wires and sections as indicated on the wiring diagram for every model.
The connection can be made either through the back or by the side of the units. In case of connection by the side, the lid of the
connections must be mounted through the cable before carrying the connections.
Fix the cable with the clamp provided and mount the front cover.
When mounted in series the power supply line must be the same for all the COR air curtains and maintain electrical phase order.
OPERATION
Each air curtain incorporates a remote control (radiofrequency) included inside the packing.
REMOTE CONTROL SYNCHRONIZATION
When the air curtain receives power supply for the fi rst time, within next 30 seconds the internal receiver remains in synchronization
mode. In this period is required to synchronize the remote control pressing simultaneously 2 and holding down this, press down
button number 5 (fi gure 8 and 9). When the process is done correctly, LED num. 1 will do a sequence of fl ashes.
11