IMPORTANT!
• The standard steam unit comes with 6 feet (1.8m) of steam hose. The Room Steam Kit comes with
9 feet (2.7m) of 3/8" ID hose.
• The maximum total length of rubber steam hose is 12 feet (3.7m).
• The maximum total length of insulated copper tubing may be up to 20 feet (6.1m).
• The maximum combined allowed length of steam hose and insulated copper tubing is 32 feet
(9.75m).
• In all cases, minimize sharp bends and elbows. Use 2 - 45° elbows instead of 90° elbows.
• Hose inner diameter 7/8" (22 mm); outer diameter 1 ¼" (30 mm).
• Additional steam hose is available GFI #7513 / CGF #GF-20-2.
5.1 INSTALLATION
Attach the air filter to the grille. Install the grille over the housing face and use the provided screws
and pre-drilled holes to secure the grille to the RMB housing. The steam manifold will extend out
past the face of the grille. The grille may be painted to match decorations in the home.
IMPORTANT!
Use only the grille that was provided with the room steam kit. Any alterations or changes to the
grille may result in water leakage and damage to the home.
5.2 MAINTENANCE
The air filter should be vacuumed or rinsed with water at least once per year. More frequent
cleaning may be necessary depending on home conditions. Neglecting the air filter (cleaning and/
or replacement) will seriously affect the operation of the room steam unit.
NOTE: For new construction, the air filter must be cleaned as needed during construction and
again when construction is complete.
5.3 START UP
The RMB blower will operate when the humidifier has a demand for humidity. Operation will
continue for 30 seconds after the demand is complete.
5. ROOM STEAM KIT GRILLE
Page | 15
ENG
Part No. 5500-33 Rev B
Code: +03U400150 REV 4.2 20210708