Discharge Pipe Assembly; Electrical Connection; Pre-Start Checks; Starting - ESPA LEADER BORA33 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
If the well water level fluctuates significantly,
we recommend installing level electroprobe
equipment.
To avoid ruining the motor power cable and
level electroprobe cables, attach them to the
discharge line with clamps when lowering
them into the well.

3.1. Discharge pipe assembly

The pumps are supplied ready to be connected a 1"
line.
However,
if
the
considerable and the paths are long and winding,
we recommend using lines with a larger diameter,
to avoid head loss due to friction as much as
possible
and
to
obtain
performance possible.
Install a check valve on the outlet of the pump to
prevent the line from emptying every time the pump
stops.
If a plastic hose is chosen instead of a metallic line,
make sure it can withstand the pressure provided
by the pump. Prevent the hose from becoming
twisted because, in addition to preventing the
desired flow, proper pump operation will be
hindered.

3.2. Electrical connection

The electrical installation must have a multi-
pole isolator with minimum 3mm contact
openings, The protection of the system will
be based on a differential switch (Δfn = 30mA)
The connection and its dimensioning must be
performed by a qualified installer according
to the needs of the facility and following the
regulations in force in each country.
To lengthen the electrical cable, use resin
connection splices only. Pay special attention
ensuring that the colors of pump cables
match those of the extension.
It is imperative to connect the ground cable
(yellow-green color).
In the single-phase motors with external
capacitor, connect the capacitor together with
the protective panel to the outside of the well.
Thermal protection must be provided by the
user (in accordance with current installation
rules).
For correct electrical connection, follow the
diagrams in fig.2.
geometric
height
is
the
best
hydraulic
9
3.3. Verifications prior to initial start-up
Make sure the mains frequency and voltage
match the indications of the nameplate. Make
sure the value of the capacitor is the same as
described on the plate (single-phase version
only).
Check
that
the
submerged. If the flow is less than expected,
invert two phases of the power supply in the
protective panel (three-phase version only).
NEVER LET RUN THE PUMP DRY.

4. STARTING

If there is a line valve, open it completely.
Connect the power supply switch. Water will never
fow at the end of the line immediately; if the path is
long, wait a few minutes. Check that the absorbed
current is the same as marked on the nameplate
and adjust the thermal relay accordingly (three-
phase version only).
If the motor does not start or no water flows at the
end of the line, try to find the anomaly using the
troubleshooting guide in point 9.

5. MAINTENANCE

These submersible pumps do not require maintenance.
During frosty periods, remember to drain the
line.
If the pump will be out of service for extended
periods, it should be removed from the well
and stored in a dry, well-ventilated location.
Warning: In the event of faults or damage occurring
to the pump, repairs should only be carried out by
an authorised service agent.
The
Official
Technical
www.espaleader.eu.

6. DISPOSING OF THE PRODUCT

When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.