Fisher Bioblock Scientific IPC Mode D'emploi page 37

Table des Matières

Publicité

Hinweis
Die IPC hat beim Einschalten eine
Verzögerung von 3 Sekunden, bis
die serielle Schnittstelle zuverlässig
anspricht.
Please note
When switching the IPC on,
the serial interface will only
respond after a delay of 3 seconds.
Remarque
La pompe IPC a un retard de 3
secondes lors de la mise en route
jusqu'à ce que l'interface sérielle
fonctionne de manière fiable.
TxD
GND
Sendedaten
Masse
Transmitted Data
Signal Ground
Données envoyées
Prise de terre
du système
RxD
Empfangsdaten
Received Data
Données reçues
Kommunikationsparameter
Communication parameters
Paramètres de communication
Standardeinstellung
Default setting
Réglage standard
9600 baud, 8 bit,
1 stopbit, no parity
Alternative
1200 baud, 8 bit,
1 stopbit, no parity
36
Serielle Schnittstelle
RS232 IN (Eingang, weiblich)
Der Anschluss erfolgt über eine
9-polige D-Buchse.
Adressierung.
Jeder Befehl beginnt mit der
Pumpenadresse (1–8). Sie ist
werkseitig auf 1 eingestellt und
kann mit @ verändert werden
(siehe auch Grundeinstellungen
Seite 16).
Die Adresse wird permanent
gespeichert (d.h. auch nach
Ausschalten des Antriebs).
Die Adressierung ermöglicht die
Ansteuerung von bis zu 8
Ismatec
®
-Pumpen mit einer
RS232-Schnittstelle.
Aufbau der Befehle.
Nach der Adresse folgt ein Zeichen
als Befehl. Manche Befehle haben
zusätzlich einen Parameter, der aus
4 bzw. 5 Ziffern besteht.
Der Befehl wird mit einem carriage
return (ASCII 13) abgeschlossen.
Die meisten Befehle quittiert die
Pumpe mit einem Stern *. Ja/Nein-
Abfragen beantwortet sie mit + (ja)
oder – (nein).
Mehrstellige Antworten werden
mit (cr) ASCII 13 und (lf) ASCII 10
abgeschlossen.
Fehlerhafte Zeichensequenzen
werden mit # quittiert.
Zahlenwerte gibt die Pumpe als
drei- bis fünfstellige Zahl zurück.
Vier dieser fünf Stellen sind
Ziffern, eine Stelle ist entweder
ein Dezimalpunkt oder eine füh-
rende Leerstelle.
Serial interface
RS232 IN (female)
A 9-pin D-socket is available on
the rear panel of the pump.
Setting the pump address.
Each command string begins
with the pump address (1–8).
It is factory-set at 1 and can be
changed with @ (also refer to the
basic settings described on page
16).
The address will be stored
permanently (even after the
pump has been switched off).
The assignment of the address
enables the user to control up to
8 Ismatec
®
drives via one
interface.
Structure of the commands.
The address is followed by a
character. Some commands have
an additional parameter which
always consists of 4 or 5 figures.
The command string is com-
pleted by a carriage return
(ASCII 13). The pump confirms
most of the commands with an
asterix *. Yes/No inquiries are
answered by + (yes) or – (no).
Multi-digit replies are concluded
by (cr) ASCII 13 and (lf) ASCII 10.
Incorrect command strings are
answered by #.
Numerical values are confirmed
as 3 to 5-digit figures. Four of the
five digits are numerals, one digit
is either a decimal point or a
preceding blank space.
Interface sérielle
RS232 IN (entrée femelle)
Le raccordement se fait par le
biais d'une douille D à 9 pôles
(femelle).
Adressage
Chaque commande commence
avec l'adresse de pompe 1–8. Elle
est réglée par défaut sur 1 et
peut être modifiée avec @ (voir
réglage de base, page 16).
L'adresse est enregistrée de
manière permanente (c'est-à-dire
également après la mise hors
service du moteur). L'adressage
permet la commande de plu-
sieurs moteurs Ismatec
®
par le
biais d'une seule et même
interface RS232.
Structure des commandes
Un signe suit l'adresse en tant que
commande. Certaines commandes
ont en outre un paramètre com-
portant toujours 4, respectivement
5 chiffres.
La commande se termine par
un retour à la ligne (ASCII 13). La
pompe quittance la plupart des
commandes avec une étoile *.
Elle répond aux questions oui/
non avec + (oui) ou - (non).
La pompe termine les réponses
multipositions avec (cr) ASCII 13
et (If) ASCII 10.
Les séquences de signes erro-
nées sont quittancées avec un #.
La pompe renvoie les valeurs
chiffrées sous forme de nombre
de trois à cinq positions. Quatre
de ces cinq positions sont des
chiffres, une position étant soit
un point décimal, soit un blanc
en première position.
IPC/IPC-N/Ismatec SA/18.07.00/CB/GP

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ipc-n

Table des Matières