Conducto vacío (para suministro
de corriente y conductor equipotencial)
desde la distribución secundaria hasta
FOOT BATH 
25 mm
Ø
Cable del conductor equipotencial
para FOOT BATH 
Se recomienda un fi   ltro principal (reversible) además de los 
fi   ltros en las válvulas angulares.
Válvula reductora de la presión detrás del contador de agua 
(tubería principal)
Símbolo de identifi cación
Declaración propia
Notes regarding planning
US
Plumbing
Connect (HW + CW) 2x DN 15 – NPS 1/2" using angle valves
with integrated fi   lter (included in scope of delivery). 
In addition to the fi   lters in the angle valves, a main fi   lter 
(backwash-capable) is recommended.
The customer must provide a pressure-reducing valve
downstream of the water meter (main line).
If a circulation line is used (DN 12), the connection of the cir-
culation line must be at least 24" away from the angle valves.
Calculate the pipe network according to DIN 1988, EN 806.
A pressure test of the overall installation (without angle valves)
with 1.5 times the max. permissible operating pressure is
absolutely required. Please consult the currently valid regulati-
ons for the exact procedure for the pressure test (preliminary/
main test) depending on the pipe material used. Create a test
report.
Flushing of the overall installation with clean water is abso-
lutely required (the valid guidelines for the fl   ushing are to be 
observed). Create a fl   ushing report. Flushing is to be carried 
out no later than mounting of the FOOT BATH and commissi-
oning.
An inspection opening for the affusion pipe and for the elec-
trical components and water connections is to be provided
by the customer. If the operating elements are installed in the 
wall, installation with metal stud framing is mandatory. The
pre-assembly kit of the operating elements and the con-
necting cables must be assembled when the curtain wall is
closed.
Area of application
The devices are not designed for outdoor use. If use in 
environments containing steam, chlorine or salt is planned,
consultation with Dornbracht is recommended.
Water hardness
Recommended water hardness: 0.34 - 0.39 ppm CaCO
If the water is harder, a water softener is to be installed in the 
main cold water supply line.
Hot water provision
An individual determination of requirements (e.g. acc. to DIN 
4708-2) is absolutely required to select the optimum device
for the hot water tank, taking into account additional tapping
points and simultaneous use. If the hot water temperature in 
the hot water tank is set to more than 60° C, a thermostatic
mixing valve must be installed downstream of the tank (e.g.
for a solar-heated boiler). If periodic object-based thermal 
disinfection is required, an appropriate (manual or automatic
operation) bypass of the thermostatic mixing valve must be
provided.
Outlet
Outlet capacity / connected load [CL] 0.24 gps,
drain pipe DN 50 – NPS 2".
máx. 14 m
Service
4 mm²
The integrated BA-type backfl   ow must be regularly serviced by 
a  qualifi   ed  installer.  Proper  functioning  is  tested  after  the  fi   rst 
year of operation and thereafter periodically depending on the
operating conditions, but after 1 year at the latest. A test report
is to be prepared. The angle valve fi   lters and the fi   lters installed 
by the customer must be cleaned at least once a year and, if
necessary, replaced.
Electrical system
Make electrical connections only when the components are
not under power. Electrical installation is to be carried out
by an electrician according to VDE 0100. Divergent national
regulations are to be heeded.
The pre-assembly kit of the operating elements (for wall as-
sembly) and the connecting cables must be assembled when
the curtain wall is closed.
The devices may be connected only to original Dornbracht
components.
The maximum distance between the sub-distribution or the
main distribution and the FOOT BATH is 45 feet 
(conduit
1").
Ø
The following circuit breakers and electrical components are
to be provided by the customer:
- Protective circuit breaker (30 mA, 2-pin, type A)
- Circuit breaker (6 A, type B)
- Contact breaker (16 A, 1S, 230 V AC).
Technical data
US
Plumbing
Flow rate at a fl ow pressure of 45 psi (max.)
- Affusion pipe
- WATER FALL with PEARLSTREAM 
- Massage jets
Choreography fl ow rate
- RELAX (15 Min.):
- VITALIZE (5 Min.): 
Flow pressure
Minimum fl   ow pressure  
Maximum fl   ow pressure  
Maximum fl   ow pressure difference 
between hot and cold water
Recommended fl   ow pressure  
FOOT BATH is intrinsically safe according to DIN EN 1717
3
Permitted operating temperatures
Hot water temperature range  
Thermal disinfection (3-10 Min.) 
Cold water temperature range  
Scalding protection provided at factory  
Electrical system
Sink
Electrical connections (input voltage)
in the sub-distributor
Electrical connections (input voltage)
in the FOOT BATH 
3.6 gpm
3.9 gpm
2.5 gpm
max. 26.4 gallons
max. 10.6 gallons
35 psi
60 psi
15 psi
45 psi
120-150 °F
167 °F
41-68 °F
109 °F
100-240 V AC
12 V DC
53