Télécharger Imprimer la page

Wine Guardian CS025 Guide D'installation Rapide page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
3.
Installing Thermostat (Wired)
A.
Unit is supplied with 50 feet (15 meters) of cable
with RJ-9 type connection to the Remote User
Interface Controller.
B.
Disconnect wire from back of controller and route
the cable to the desired mounting location within
the room.
C. Locate Remote User Interface within the room
midpoint on a wall in an area with good airflow
and away from any windows or heat sources.
Remove back plate of controller and mark
D.
mounting points at desired location.
E.
Drill two 1/8" (3 mm) holes and insert anchors
within mounting surface. Anchors may not be
required if securing to wall studs or racking.
Insert screws into the anchors and test fit the
installation of the backing plate tighten/loosen
screws to create a snug fit.
F.
Provide 3/4" (19 mm) diameter hole within wall or
racking structure to provide clearance for RJ-9
connection at the back of the controller.
G. Re-attach front cover plate by screwing it into
place on the back plate.
H. Connect RJ-9 cable to the back of the remote
user interface and attach to the wall at the screw
locations
I.
Reconnect cable to side of Wine Guardian unit at
either COM1 or COM2.
Note: For wireless installations or multiple
remote interfaces, refer to the full version manual
located at
wineguardian.com/manuals
4. Condensate Drain
A.
Wine Guardian ceiling systems come equipped
with a condensate pump system. Connect the
drain line to the barbed fitting at the unit and run
the drain line to the nearest drain location.
5

Publicité

loading

Ce manuel est également adapté pour:

Cs050Wgc60