Replacing Aroma and aquaCool
media
REPLACING THE AQUACOOL CANISTER
If the aquaCool canister is empty, corresponding
messages are displayed, and aquaCool switches off
shortly afterwards.
Figure 30
Page
Open the bench part.
39
Unlock the retaining bracket.
Keep the hose end including the lid in a clean
plastic bag while replacing the canister.
Replace the tin.
REPLACING THE AROMA TIN
When the Aroma tin is empty, a corresponding
message is displayed.
Attention!
Do not use any agents other than aquaCool
and Aroma gel supplied by KBL!
Risk of infections
Function of nozzles impaired
46
U t i l i s a t i o n e t M a i n t e n a n c e |
All manuals and user guides at all-guides.com
Figure 31
Page
Open the bench part.
39
Unlock the retaining bracket.
Replace the tin.
Reset the Aroma counter in the service
menu to 0 (Reset). Then the message on the
display will disappear.
Replacing the aquaCool nozzles
After 1,000 hours of operation, the aquaCool nozzles
must be replaced in order to ensure that the aquaCool
system functions properly. The assembly instructions
are included with your spare parts delivery.