Télécharger Imprimer la page

Wine Guardian SS018 Guide D'installation Rapide page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Model #
SS018
CS025
DS025
CS050
DS050
DS088
DS200
WGS25
WGC60
WGS40
WGS75
WGS100
WGS175
1
XLA – Extreme Low Ambient Option
On/Off
Note:
For wireless installations, or connecting remote interface and/or
sensors, refer to the full version manual located at
manuals
Assuming a 25' Line-Set Installation
Total
Holding
Charge
Charge
Required
Present
60Hz Models
47 oz
58 oz
59 oz
66 oz
55 oz
105 oz
108 oz
50Hz Models
50 oz
64 oz
58 oz
64 oz
106 oz
110 oz
4.
Wiring the Unit for Power
A.
Connect line power to the contactor inside the condens-
ing unit as shown. (220v)
B.
Run 24 volt low voltage signal wires from Y and C termi-
nals on fan coil to Y and C connections in condenser
housing (shown in image to the left).
C. Turn on power to the condensing unit 24 hours prior to
system start-up to allow crankcase heater to warm up
compressor.
*See page 21 in owners manual for full wiring schematic.
Inside of condensing unit also contains schematic.
5.
Turn Unit On
A.
Press the On/Off button on the systems Local Interface.
The User Interface is preset to a room temperature of
55°F
(13°C).
B.
Press the "Up" arrow once. The display will show the
existing temperature setpoint. Press the "up or down"
arrow buttons to adjust the temperature to the desired
setpoint
C. The system will turn on after a 5-minute time delay and
the cold air section will start to deliver cold air. Contact
Air Innovations if the system fails to turn on.
Charge
That Must
Be Added
16 oz
31 oz
16 oz
42 oz
16 oz
43 oz
16 oz
50 oz
16 oz
39 oz
16 oz
89 oz
16 oz
92 oz
16 oz
34 oz
16 oz
48 oz
16 oz
42 oz
16 oz
48 oz
16 oz
90 oz
16 oz
94 oz
5
Additional
Charge to add
1
for XLA
option
4 oz
4 oz
4 oz
4 oz
4 oz
6 oz
6 oz
4 oz
4 oz
4 oz
4 oz
6 oz
6 oz
wineguardian.com/

Publicité

loading