Problem
Waste discharge pres-
sure stops or decreas-
es dramatically.
The pump operates,
but no liquid is ex-
pelled.
The motor will not run.
The pump turns off on
its own.
How do I disassemble
the system to check
for an object lodged in
the pump?
Warranty
For defi ned warranty terms, review the one-page warranty
statement - see www.thetford.com.
Please give Serial Number (located on the
NOTICE
pump or manual sticker) for calls to customer
service and warranty issues.
®
SANICON
Turbo - Model 600S

Troubleshooting

Solution
Are the holding tanks empty?
With pump on, look for location
where hose expansion differs;
check for obstruction at that
point.
Turn the pump switch to the Off
position:
To CHECK FOR OB-
STRUCTION IN HOSE
(
): Visually check for
K2
foreign matter lodged in
the hose by running your
hand along hose.
TO CHECK FOR OB-
STRUCTION IN IMPEL-
LER: Refer to "Obstruction
Removal" topic.
Failure to clear a clog could
cause damage to the pump,
which will void the warranty.
Are the holding tanks empty?
Check that the RV gate valves
are open.
Pump may be clogged.
Make sure:
Pump is turned on.
RV battery is charged.
Circuit breaker/fuse is function-
ing.
Pump is receiving voltage.
Foreign object is not preventing
impeller operation.
See "Thermal Cut-Off Switch"
topic under "Overview" section
of this document.
Refer to "Obstruction Removal"
topic in "Operation" section of
this document.