6 Installation
6.1 Installing the pump tank
We recommend filling the tank with water
at room temperature. If using the pump at
temperatures below 3°C (37.4°F) add some
glass cleaner antifreeze liquid to the water.
The antifreeze liquid will cause irreparable
damage to the germanium windows. Do not
use antifreeze liquid but add ethyl alcohol
in 20% solution.
Install the pump with 30m pressure head in
places protected from heavy rain.
The product must be fastened with suitable
equipment. The fastening means must
guarantee the mechanical seal when a force
equal to at least 3 times the weight of the
device is applied.
Attach the metal cage (01) firmly to a wall using the
holes provided for this (02).
Fig. 1
Water tank 5l (1.3gal), 5m (16ft) delivery.
MNVKWAS_1511_EN
Fig. 2
01
02
Fig. 3
Take the plug out of the tank, along with any pumps
and level gauges. Remove the tank from the metal
cage.
Water tank 23l (6gal), 5m (16ft) or 11m (36ft) delivery.
Water tank 23l (6gal), 30m (98ft) delivery.
01
02
01
02
3