Jung 500.600.110 Instructions D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

eNet actionneur de commutation / à poussoir 8 voies / actionneur volet
roulant 4 voies, modulaire
Priority, restraint
Activate force operation blind
position
Recall forced operation slat
position
Deactivate force operation
blind position
Deacitvate forced operation
slat position
Priority, wind alarm
Activate wind alarm blind posi-
tion
Recall wind alarm slat position 0 ... 100 %
Deactivate wind alarm blind
position
Deacitvate wind alarm slat po-
sition
Priority, sun protection
Activate sun protection blind
position
82581933
J0082581933
0...4
Basic setting: 2
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0...4
Basic setting: 3
0 ... 100 %
Basic setting: 0 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
0...4
Basic setting: 0
0 ... 100 %
Basic setting: 100 %
18/20
Specifies the priority for recal-
ling and removing a scene of
type Restraint for the channel.
Defines the behaviour of the
output on activating the forced
operation.
Defines the slat position of the
output on activating forced
operation. Only visible when
the Venetian blind operating
mode is set.
Defines the behaviour of the
output on deactivating the for-
ced operation. Only visible
when the priority for the forced
operation is 0.
Defines the slat position of the
output on deactivating forced
operation. Only visible when
the priority for the forced ope-
ration is 0 and the Venetian
blind operating mode is set.
Specifies the priority for recal-
ling and removing a scene of
type Wind alarm for the chan-
nel.
Defines the behaviour of the
output on activating the wind
alarm.
Defines the slat position of the
output on activating the wind
alarm. Only visible when the
Venetian blind operating mode
is set.
Defines the behaviour of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0.
Defines the slat position of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0 and the Venetian blind
operating mode is set.
Specifies the priority for recal-
ling and removing a scene of
type Sun protection for the
channel.
Defines the behaviour of the
output on activating the sun
protection.
23.03.2017