Jung 500.600.110 Instructions D'utilisation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

eNet actionneur de commutation / à poussoir 8 voies / actionneur volet
roulant 4 voies, modulaire
Switch-off warning
Priority, lock-out protection
Activate lock-out protection
switching state
Deactivate lock-out protection
switching state
Priority, restraint
Activate forced operation swit-
ching state
Deactivate forced operation
switching state
Priority, wind alarm
Activate wind alarm switching
state
Deactivate wind alarm swit-
ching state
Priority, sun protection
Activate sun protection swit-
ching state
82581933
J0082581933
On, Off
Basic setting: Off
0...4
Basic setting: 1
On, Off
Basic setting: Off
On, Off
Basic setting: Off
0...4
Basic setting: 2
On, Off
Basic setting: On
On, Off
Basic setting: Off
0...4
Basic setting: 3
On, Off
Basic setting: Off
On, Off
Basic setting: Off
0...4
Basic setting: 0
On, Off
Basic setting: On
14/20
If the switch-off warning is ac-
tive, the light is not switched
off directly. The light goes off
30, 15 and 6 seconds before
permanent switch-off. During
the switch-off warning, a
switch-on telegram effects di-
rect switch-on. It is not pos-
sible to terminate the time
using a switch-off telegram.
Specifies the priority for recal-
ling and removing a scene of
type Lock-out protection for
the channel.
Defines the behaviour of the
output on activating the lock-
out protection.
Defines the behaviour of the
output on deactivating the
lock-out protection. Only vi-
sible when the priority for the
lock-out protection is 0.
Specifies the priority for recal-
ling and removing a scene of
type Restraint for the channel.
Defines the behaviour of the
output on activating the forced
operation.
Defines the behaviour of the
output on deactivating the for-
ced operation. Only visible
when the priority for the forced
operation is 0.
Specifies the priority for recal-
ling and removing a scene of
type Wind alarm for the chan-
nel.
Defines the behaviour of the
output on activating the wind
alarm.
Defines the behaviour of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0.
Specifies the priority for recal-
ling and removing a scene of
type Sun protection for the
channel.
Defines the behaviour of the
output on deactivating the sun
protection. Only visible when
the priority for the sun protec-
tion is 0.
23.03.2017

Publicité

Table des Matières
loading

Table des Matières