Mitsubishi Electric CITY MULTI PLFY-EP NEMU-E Série Manuel D'installation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Electrical work
Select: SELECT
If all outlets are selected,
next time the unit goes into operation.
Navigating through the screens
• To return to the previous screen .....[RETURN] button
The current vane setting will appear.
Select the desired outlets from 1 through 4 with the [F1] or [F2] button.
• Outlet: "1", "2", "3", "4", and "1, 2, 3, 4, (all outlets)"
Press the [F3] or [F4] button to go through the option in the order of "No setting (reset)",
"Step 1", "Step 2", "Step 3", "Step 4", and "Step 5".
Select the desired setting.
■ Vane setting
No setting
Step 3
Draft
reduction*
* Draft reduction
The airflow direction for this setting is more horizontal than the airflow direction for
the "Step 1" setting in order to reduce a drafty feeling. The draft reduction can be
set for only 1 vane.
Press the [SELECT/HOLD] button to save the settings.
A screen will appear that indicates the setting information is being transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4) when the
transmission is completed.
Make the settings for other outlets, following the same procedures.
en
9
Manual vane angle
Outlet
Angle
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Setting
will be displayed the
Step 1
Step 2
Step 4
Step 5
All outlets
Confirmation procedure
Manual vane angle
M-NET address
1
Identify unit Check button
Input display: SELECT
Address
Check
Manual vane angle
M-NET address
1
Function setting for unit
with vane fully open.
Return: RETURN
Manual vane angle
No communication
Check Unit state.
Return: RETURN
1 Select the "M-NET address" for the
units to whose vanes are to be fixed,
with the [F2] or [F3] button.
Press the [F4] button to confirm the unit.
2 After pressing the [F4] button, wait
approximately 15 seconds, and then
check the current state of the air con-
ditioner.
→ The vane is pointing downward. →
This air conditioner is displayed on the
remote controller.
→ All outlets are closed. → Press the
[RETURN] button and continue the
operation from the beginning.
→ The messages shown to the left are
displayed. → The target device does
not exist at this refrigerant address.
• Press the [RETURN] button to return to
the initial screen.
3 Change the "M-NET address" to the
next number.
• Refer to step 1 to change the "M-NET
address" and continue with the confir-
mation.

Publicité

Chapitres

Table des Matières
loading

Table des Matières