7. Electrical Wiring

Choice of the relay: The type of relay that needs to be selected depends on the type of
flashing light of the system. For example: When you use a 230V flashing light, you should
use a relay with a voltage of 230V.
1
Brown
2
Grey
3
Black
4
Black
5
Blue
Control signal
Control signal

8. FAQ

• What happens if the ground stop is contaminated with eg. sand ?
Due to the internal obstacle detection, the extending bolt of the Electradrop will stop sliding
down whenever he encounters an obstacle.
• What happens if the power cable of the Electradrop is cut through ?
The Electradrop will remain in its current position
• In case of power failure, how can I remove the Electradrop ?
The Electradrop can be unlocked by the cylinder so you can slide up the Electradrop afterwards.
12
Plus-pole of the power supply 24 V DC (+)
Warning light (flasher) coming from the relay
Optional: Reading out the position of the dropbolt.
Nul-pole of the power supply 0 V DC (-)
Connecting parallel over the flashing light of the gate.
1
2
3
4
5
Optional dropbolt position detection
3
+
4
-
3
Umax = 200V AC/DC
Imax = 1A AC/DC
3
4