Installation and Maintenance
Caution! Before installation, disconnect the power network where you are
planning on installing the fan.
Caution! Installation may be carried out only by a qualified electrician.
Before mounting, the cover part of the ventilator must be removed by turning it counterclockwise and
simultaneously pressing with a flat-blade screwdriver on the lock under the case (Image 1). The ventilator
must be mounted in a ventilation duct by attaching the ventilator on the wall by the use of screws (Image 2).
The base model ventilators, ventilators with a timer (T), ventilators with a humidity sensor and timer (HT)
must be connected to the electrical network. Under the cover, there are N-L or N-L-S clamps to which the
electrical network must be properly connected (Images 3-5). When connecting the ventilator with the voltage, it
is important to observe polarity and connect the line wire with L-clamp and neutral wire with N-clamp. When
connecting the fan to electricity, it is important to take into account polarity and connect the live wire to the
Terminal L and the neutral wire to the Terminal N.
In case if the fan is directly connected to the electric power network, the power network must be equipped with
a switch that ensures safe disconnection of the power supply.
Timer T
The fan is turned on by the S1 power switch (Drawing 4) or by turning on the light (Drawing 5). After turning
off the light or the switch, the fan continues its operation for a specific time interval that is set up by a controller.
This interval may be 1 to 30 minutes long.
Caution! The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.
Humidity Sensor HT
The fan is equipped with a humidity level control that may be used to set the level of humidity from ~60%RH -
~90%RH and a delay control that may be used to set the delay from 1 to 30 min. The fan is turned on automatically
when a certain humidity level is reached in the room or it may be turned on manually by a switch. Connection
diagram is shown in Drawing 4-5. The fan is turned off after a pre-set time interval. Humidity "H" and delay
"T" controllers are located on the control unit (Drawing 7). To set the maximum humidity level (~ 90% RH) for
moisture regulator "H" need turned fully clockwise.
Caution! The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.
12V motor - 12
The fan is equipped with a 12V motor. A fan intended to be installed together with 12V power supply.
Caution! Fans with electronic control unit must be adjusted before they are connected to the power
network.
Caution! If the potentiometer is set to "1 min", the fan will turn on for a couple of seconds after
connected it to the power network.
Guarantee
Producer guarantee is 24 months.
In the case of damages contact the place of trade.
The guarantee does not cover:
1. noted mechanical or other damages
2. mechanical or other damages caused by incorrect or improper usage, misuse, abuse or neglect
3. mechanical or other damages caused by incorrect installation or by product's incorrect fitting to
insufficient or unsuitable power
4. mechanical or other damages caused by ignoring the instruction manual conditions
A guarantee does not cover natural wear of the product.
Utilization
Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical
and electronic equipment should not be disposed of as general household waste at its end-oflife.
Instead, the products should be handed over to the appliance collection points for the recycling
of electrical and electronic equipment, recovery and recycling in accordance with your national
legislation and the Directive 2002/96/EC and 2006/66/EC.