3.3
Connections for the temperature sensor in
the terminal box
1
Fig. 5
[1] ON/OFF for solar inverter
[2] Temperature sensor NTC
(sensor pocket in the middle of the cylinder)
[3] Temperature sensor NTC
(the auxiliary system's coil inlet)
[4] Terminal strip in the terminal box
6
4
3
2
6720805338-03.1V
3.4
"Heat pump – solar system" connections
6
7
Fig. 6
[1] Solar controller
[2] Temperature sensor NTC (NTC COIL – coil)
[3] Solar controller temperature sensor NTC
(in the middle of the cylinder)
[4] Pump
[5] Solar collector
[6] Solar collector temperature sensor NTC
[7] Temperature sensor NTC
(NTC TANK – in the middle of the cylinder)
Install the temperature sensor in the middle of the cylinder
Ensure the temperature sensor and cylinder make
good contact.
▶ Make sure that the temperature sensor is
positioned correctly in the sensor pocket so that
the temperature will be measured accurately.
▶ Install the installation set [1], temperature sensor NTC of
the accessory [2] and the temperature sensor NTC of the
control unit [3] and position them as shown in Fig. 7.
▶ Push the temperature sensor into the sensor pocket as far
as it will go.
▶ Fasten it using the cable tie supplied.
▶ Secure fastening clip [4].
▶ Connect the terminals of the temperature sensor NTC in
the terminal box to the "NTC TANK" terminals.
2
1
3
4
6720805338-02.2V
6 720 821 590 (2019/10)