   Programming With Push Buttons
EN
When to switch off devices after the area is vacated
Press the Time button
set the time to wait before
switching off devices in the
circuit (default 20 minutes). The
number of presses sets the time:
To find the current Time setting
Press and hold the Time button
for more than 3 seconds.
The number of LED flashes
indicates the setting:
To test the device has learnt the commands
Press and hold
for more than 3 seconds. The air con will
l
turn on if the ON commands has been correctly programmed.
Press and hold
for more than 3 seconds again. The air
l
conditioning will turn off if the OFF commands has been
correctly programmed.
to
# Presses
1
10 seconds
2
3
4
5
# Flashes
1
10 seconds
2
3
4
5
To learn proprietary infrared commands
ON:
Time
1. Press
5 minutes
ON command. This Learn mode is active for 10 sec.
10 minutes
2. Point the air conditioning controller at the device and send the
20 minutes
ON command, as described by the manufacturer's instructions.
30 minutes
If the command has been correctly learnt, the LED in the
device flashes slowly; if not, it flashes quickly.
OFF:
Time
1. Press
conditioning OFF command. This Learn mode is active for 10
seconds.
5 minutes
2. Point the air conditioning controller at the device and send the
10 minutes
OFF command, as described by the manufacturer's
20 minutes
instructions. If the command has been correctly learnt, the LED
30 minutes
in the device flashes slowly; if not, it flashes quickly.
To lock the programmed settings
Press and hold either button
seconds to toggle between lock and unlock. This locks the sensor
if the LED lights up while pressing the button. This unlocks the
sensor if the LED doesn't light up but flashes once after 10
seconds.
once to get the device ready to learn the air con
twice to get the device ready to learn the air
or
for more than 10

Publicité