Manual Access Point SAnR/SAtc
italics as in this paragraph) must always be
observed!
2.

Conformity with standards

CAN/CSA C22.2 No. 61010-1-12
Safety Requirements for Electrical Equipment
for Measurement, Control, and Laboratory Use
- Part 1: General Requirements - Third Edition
ANSI/ISA-61010-1 3rd Edition
Safety Requirements for Electrical Equipment
for Measurement, Control, and Laboratory Use
- Part 1: General Requirements - Third Edition
CAN/CSA C22.2 No 60079-0:19
Explosive atmospheres - Part 0: Equipment -
General Requirements
UL No 60079-0:19
Explosive atmospheres - Part 0: Equipment -
General Requirements
CAN/CSA C22.2 No 60079-15:18
Explosive atmospheres - Part 15: Equipment
protection by type of protection "n"
UL No 60079-15:20
Explosive atmospheres - Part 15: Equipment
protection by type of protection "n"
UL No 60079-31:15
Explosive atmospheres - Part 31: Equipment
dust ignition protection by enclosure "t"
CSA C22.2 No 213
Nonincendive electrical equipment for use in
Class I and II, Division 2 and Class III, Divisions
1 and 2 hazardous (classified) locations
UL121201
Nonincendive Electrical Equipment for Use in
Class I and II, Division 2 and Class III, Divisions
1 and 2 Hazardous (Classified) Locations
3.

Technical data

3.1
Marking
Class I, Zone 2, AEx nR IIC T6
Class II, Zone 22, AEx tc IIIC T80°C
3.2
Certification QPS
QPS LR1702-1
3.3
Enclosure ingress protection
Minimum degree of protection IP66
Edition June 2021
Copyright
thuba Ltd., CH-4002 Basel
Switzerland