Télécharger Imprimer la page

Publicité

EN

TECHNICAL DATA

Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
It's recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_______________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In order to get your device work correctly and fine in time, must ensure compliance with the
mode of installation and maintenance described in this booklet. Relying on a qualified plumber.
Make sure that the system is free from all debris and impurities existing.
INSTALLATION
Fig. 1: Make the hole in the worktop for the spout (MIN Ø23 mm - 0.90 in, MAX Ø38 mm - 1.49
in). Insert the rod into the rosette by placing the flat gasket under it. Insert the rod in the hole
and fix it in the lower part with the fixing kit, finishing the locking by tightening the screws.
Fig. 2: For the mixer and the diverter, remember that the maximum thickness of the worktop
must be 20 mm - 0.78 in.
Fig. 3: Make the hole in the worktop for the mixer (Ø40 mm - 1.47 in). Pre-screw the screws
on the mixer body by positioning the ring and the gasket. Insert the mixer unit from under the
worktop. Screw the rosette onto the mixer body that comes out from the worktop and screw
the hexagonal ring nut to lock everything. Tight the screws from under the worktop.
Fig. 4: Position the square handle and screw the grubscrew until it is completely locked. Insert
the coverhole plug.
Repeat step 2 to 4 to install the diverter.
Fig. 5: Connect the mixer to the diverter using the quick coupling hose.
Fig. 6: Make the hole in the worktop for positioning the shower support (MIN Ø28 mm - 1.1in,
MAX Ø38 mm - 1.49 in). Insert the rod inside the hole, placing the flat gasket under the rosette.
Secure it at the bottom using the appropriate kit, tight the screws. Connect the hose to the
shower, taking care to insert the flat gasket. Insert the rest of the hose under the worktop,
through the shower holder itself.
Fig. 7: Connect the mixer to the water mains using the hoses. Connect the spout to the water
outlet of the diverter using the appropriate hose. Connect the shower hose to the diverter. Fol-
low the instructions given in the figure.
After connecting the body to the system, turn on the stopcocks and check that the mixer tap
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.
CLEANING
In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and
dry them with a soft towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid
detergents which contain corrosive or acidic substances, abrasive sponges, swab with metallic
strings because they could irreversibly compromise the surfaces.
THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE
IB RUBINETTERIE FROM ANY WARRANTY OBLIGATION.

Publicité

loading

Ce manuel est également adapté pour:

Elio eo396 2Elio eo397 1Elio eo397 2