TECHNICAL DATA

Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
It's recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_______________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In order to get your device work correctly and fi ne in time, must ensure compliance with the
mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber.
Make sure that the system is free from all debris and impurities existing.
INSTALLATION
Fig. 1: Make a MIN 100 mm - 3.93 in, MAX 110 mm - 4.33 in hole into the wall.
N.B.: MIN and MAX measure are referred to the fi nished wall, cladding included.
Fig. 2: Insert the body into the hole previously done.
Fig. 3 - 4: Connect the body to the hydric system by following the arrow printed on it in order to
defi ne the entrance and the exit. It's recommended to use hemp or PTFE to assure the enduran-
ce. Fix the recessed body taking in consideration the vertical and horizontal perpendicularity.
Do it with the help of a spirit level.
After connecting the body to the system, turn on the stopcocks and check that the mixer tap
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.
Fig. 5: Reduce the crack on the wall leaving Ø35mm - 1.37 in diameter, in order to let the gasket
laying to the cladding.
Fig. 6: Position the gasket into the marble support, inserting it into the body. Put the handle
on the broach making sure to insert the Tefl on ring. Verify the correct position of the handle in
relation to the opening/closing control. Fix the handle to the grub screw.
Fig. 7: Put the marble cover on the handle, carefully and paying attention during this process.
Once the threaded hole correspond to the cover hole, insert the grub screw.
Fig. 8: Screw the little lever into the handle body and verify the correct operation of it.