Installation:
 Loosen the four cross-head screws in the lens and remove them upwards.
The holes for mounting the housing are then accessible, for dimensions see chapter
ternative installation possible with the brackets supplied.
 Perform electrical connection on the circuit board in the lens as follows.
 Close the device again after setting the desired operating mode.
 Ensure that the sealing is clean and undamaged before assembly. (Ensure vapor tightness). Do not
use devices with damaged seals.
 Tighten the four cross-head screws of the lens crosswise in at least two rounds with a final torque of
approx. 1.5 Nm.
 Carry out a final functional test to ensure reliable signaling.
6.3

Electrical connection

S1
Selection of
operating
mode
X1
External control input
Note: Devices with DC voltage are equipped with reverse polarity protection. The function is guaranteed if the
polarity of the connections is reversed.
6.4

Setting the operating modes

S1
Operating mode
1
2
3
OFF OFF OFF
Flashing light
Flashing light
OFF OFF ON
Continuous light
OFF ON OFF
Blinking light
OFF ON
ON
Flashing light
ON OFF OFF
Blinking light
ON OFF ON
Flashing light
ON
ON OFF
Flashing light
ON
ON
ON
OFF OFF ON
Double flash mode (DFM3) see
03/2021
Quadro LED-RGB-3G/3D Operating Instructions
Light intensity control
Flashing light
Blinking / continuous light: 45 – 100%
*
1 Hz
0.75 Hz
1 Hz
2 Hz
2 Hz
0.1 Hz
0.5 Hz
Option
Page 6 / 8
10 – 100%
S1
Color assignment
4
5
6
*
OFF OFF
Red
OFF ON
Blue
OFF
Green
ON OFF
ON
ON
Yellow
*
Factory setting
3.
Dimensions.
Al-
X2 Operating voltage
connection
DC:
AC:
Connection of
the line
086200012a
Table des Matières
loading

Ce manuel est également adapté pour:

Quadro led-rgb-3d

Table des Matières