Caution
An increase in the room temperature can be
slowed by the thermostats for the radiators or
under floor heating. Therefore, open the thermo-
stats fully, except in those rooms where a cooler
temperature is required, e.g. bedrooms.
TIP
If the room temperature is constantly too low/high,
you increase/decrease the value by one step in
menu 1.1.1.
If the room temperature changes when the out-
door temperature changes, you increase/decrease
the curve slope by one step in menu 1.30.1.
Wait 24 hours before making a new setting, so that
the room temperature has time to stabilise.
HOT WATER
When there is a temporary increase in hot water demand,
this menu can be used to select an increase in the hot water
temperature for a selectable time.
You can also select "More hot water" in the main product's
menu 2.1.
VENTILATION
The ventilation in the accommodation can be temporarily
increased or reduced here.
The return time for the fan may, if necessary, be changed
in the main product's menu 1.2.5 – "Fan return time".
POOL
Here you can change the temperature of the water in the
pool or activate/deactivate heating.
PV SOLAR
You can read off the value of the power that the solar panels
are currently providing.
You can also see how much energy the solar panels have
produced during the current calendar month.
HOME/AWAY
Here you can activate or deactivate the "Away mode" func-
tion.
The function is activated if you select "Away" when you
leave your home. In order to deactivate, select "Home". The
settings for "Away mode" are made in the main product's
menu 4.5 "Away mode".
NIBE RMU S40 | EN
MENU 1 – NIGHT MODE
NIGHT MODE
Setting: On/Off
SCHEDULE NIGHT MODE
Setting: 00.00 – 23.59
You can activate night mode here.
Activate night mode during the time of day you want to
switch off the backlight.
MENU 2 – CONNECTIONS
Select wireless or wired connection.

WIRELESS CONNECTION

Select wireless connection.
Go to the main product and select menu 5.4 – "Connect
wireless units".
WIRED CONNECTION
Select a communication address for RMU S40 by allocating
it a unique number in this menu.
Setting: 1 – 8
MENU 4 – LICENCES
You can find licences for open source code here.
MENU 5 – SENSOR CALIBRATION
Here, you can calibrate the temperature sensor's value. The
set value is added to, or deducted from, the sensor's current
measured value.
Setting: -5.0 – 5.0 (Default 0)
MENU 7 – DISPLAY ZONES
Here, you can select the zones that you want to be displayed
in your RMU S40, for heating and cooling.
You can choose to display a maximum of ten zones.
MENU 8 – FACTORY SETTING
Reset to factory setting.
MENU 9 – INFORMATION
Here, information is displayed about the product and the
software version that is installed.
27

Publicité

Table des Matières
loading