SIRENA ELETTRONICA AUTOALIMENTATA PER SISTEMI RADIO XR
PROGRAMMING
1.
Press and hold the two buttons until the LED located beneath the light stays on (around 4 seconds),
then release the buttons.
2.
Enter the code using the top button for zero "0" and the bottom one for one "1". The LED will flash
each time you enter a digit correctly.
After entering the 18 digits, the LED will flash to confirm that the new code and power status have been sent to the base
unit. The system will now exit the configuration phase automatically.
OPERATION
If the LED beneath the light flashes slowly (around 3 seconds), this indicates that the siren is working.
If the LED flashes quickly, this indicates a fault in the power supply, preventing the sound and light signals from working
correctly, although the radio communication with the base unit is still intact allowing it to signal the fault.
In this case, check the power supply and, more importantly, the internal battery level.
If the LED beneath the light has switched off completely, the XR300 siren is no longer active.
The XR300 siren signals connection of the base unit with three flashes of the light, while a long flash means it is
disconnected.
If the event of an alarm, the base unit will activate the siren for a set period of time; if the siren does not receive the base
unit deactivation signal within 10 minutes, both audible and visual signals are automatically reset, leaving the light flashing
around every 5 seconds to signal the event memory.
You can also silence the siren without a signal from the base unit by pressing the green button disconnection of XR20
remote control.
The event memory is reset each time the base unit is connected, or when already connected by pressing the red button
(connection) on the XR20 remote control. If the light flashes every 5 seconds, this indicates that the siren has completed an
alarm cycle (event memory). This signal is automatically cancelled each time the base unit is connected or after 30 minutes
after connection, and can be reset, with the unit connected, by pressing the red button (connection) on the XR20 remote
control.
COLLEGAMENTI
12V
4
AL500SW
230Vca
230V
+
Remove the jumper
12V battery
-
to connect the XR20
+
remote control
13,8V
-
radio link.
Art. XR300
Operating voltage: 12V
Power supply voltage: 13,8V
Absorption in st/by: 30mA
Absorption in alarm: 2,1A
EMC/2006/95/CE
EMC/2004/108/CE
Made in Italy
12V 10W lamp