DE_Log100_Cryo_Anleitung
LOG100/110/CRYO
– Data logger
• Start-Stop-button:
Depending on the setup configuration, you can start or Stop the data log-
ger via the mentioned Start-Stop-buttons. You have to press and hold the
buttons 3 seconds. When it starts a short acoustic signal and the green LED-
will flash and the display indication will switch from STOP to LOG.
• Mode-button:
By pressing the Mode-button you will see on the bottom line the Average
(AVG)-, Minimum (MIN)- and Maximum (MAX) temperature of the recorded
measurements. If the data logger is not started it will display --- instead of
AVG, MIN or MAX temperature.
AVG:
MIN:
Average
Minimum
By using the AUTO-Mode (AUT) the display will switch automatically every
two seconds.
In LOG mode, acoustic alerts can be disabled by pressing the Mode-button
for 2 seconds (Display "Bep Off").
2.4 Display segments of LCD (Fig. 2)
• Besides the two measurements, the large LCD displays several status infor-
mation. By using the Software DE-LOG-Graph you are able to switch on or
off the display, or to setup an interval how long the display will stay on
when no button is pressed (snooze function). By using this function it is pos-
sible to prevent it displaying information to unauthorized persons.
16
11.10.2013
15:35 Uhr
Seite 9
MAX:
AUT:
Maximum
Auto-switch
LOG100/110/CRYO
F:
Measurement 1 displays the current relative humidity (Log110) or the
current temperature (Log100 / Log100CRYO).
G: Unit Measurement 1 display the current measuring unit of measurement 1.
H: Measurement 2 displays the measurement in the lower display line.
Depending on the logger model, the settings of the internal or the
external temperature measurement, average, minimum or maximum
measurements will be displayed.
I:
Unit Measurement 2 display the current measuring unit of measurement 2.
J:
MAX-MIN-AVG display the average, minimum or maximum measure-
ments.
K: Status info display the operation mode LOG or STOP. LOG indicates the
recording mode and STOP indicates standby mode.
L:
External probe EXT s displayed when an external sensor is connected. In
the lower display line the measurement 2 is corresponding with the
external sensor.
M: Lowbat indicates the capacity of the battery.
Note: °C = Celsius,°F = Fahrenheit
%rh = relative humidity, td = dew point temperature
Other display information
• In addition to the above mentioned information, the display also indicates
several other information. This information will be displayed depending
on the display settings (snooze function) and operation mode:
Display
switched off
– Data logger
connected
Logger
to the PC
configured
17