Garmin GWS 10 Instructions D'installation page 5

Masquer les pouces Voir aussi pour GWS 10:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
www.reelschematic.com
www.reelschematic.com
4. Choose from the following settings to adjust the filter:
Off— turn off the filter to make the display more sensitive to changes in the wind.
On—select a higher number to increase how sensitively the display reacts to changes in the wind speed, or select a lower number to
decrease the sensitivity.
Auto—automatically adjusts the filter settings based on wind conditions.
Configuring the GWS 10 if the Filter and Offset Selections Are Not Shown
Refer to your Garmin Chartplotter or marine instrument owner's manual for instructions on accessing configuration.
To configure the orientation:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "ANGLEOFFSET="
3. Follow the command with a number between 0 and 359, in degrees.
To configure the wind angle filter:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "ANGLEFILTER="
3. Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the
automatic setting.
To configure the wind speed filter:
1. Select Generic Configuration to specify data for the filter and offset settings.
2. Enter the following command: "SPEEDFILTER="
3. Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the
Automatic setting.
NMEA 2000 PGN Information
Use the tables to determine the approved NMEA 2000 PGN information that can be received and transmitted by a GWS 10 when
communicating with a NMEA 2000-compliant device.
Transmit
059392
060928
126208
126464
126996
130306
130312
130314
Specifications
Physical
NOTE: The width of this sensor varies with the positioning of the wind vane.
unit Dimensions:
Weight:
Cable:
Temperature Range:
Case Material
Housing and Base
Wind vane and Anemometer
GWS 10 installation instructions
ISO Acknowledgment
ISO Address Claim
NMEA - Command/Request/
Acknowledge Group Function
Transmit/Receive PGN List Group
Function
Product Information
Wind Data
Temperature
Actual Pressure
W × H × D: 19
0.6 lb (0.275 kg)
Attached NMEA 2000 cable length: 18 in. (46 cm)
5°F - 158°F (-15°C to 70°C)
PC/ABS
Polypropylene
Receive
059392
059904
060928
126208
/
- 22
/
× 11
/
× 5
/
in. (500-575 × 280 × 140 mm)
11
5
1
1
16
8
32
2
ISO Acknowledgment
ISO Request
ISO Address Claim
NMEA - Command/Request/
Acknowledge Group Function
The GWS 10 is NMEA 2000
certified.
EN
EN–

Publicité

Table des Matières
loading

Table des Matières