steps can be performed:
Access to advanced confi guration by setting both the two rotary dip switches to position '9';
Set the ID dip switch of the call module with the apartment station code that will be associated to the
fi rst button (offset);
§
The offset code can only be included between 0 and 31
Change the position of AUX dip switch no. 5 (the call module emits a confi rmation tone);
Set again the AUX dip switch no. 5 in its previous position (the call module emits a confi rmation tone);
Set again the ID dip switches in their previous position;
Exit from the advanced confi guration, by setting again the two rotary dip switches in the positions used
to program the door lock release time and the guaranteed conversation time.
Example:
The secondary call module "A" only calls users form 0 to 10 and the "B" only users from 11 to 18.
On the call module "B" access to advanced confi guration;
Set the ID dip switch to 11;
Move the AUX dip switch no. 5;
Set again all the dip switches in their previous position;
Exit from the advanced confi guration.
2Voice
power supply
BUTTON CONFIGURATION FOR SPECIAL FUNCTION
It is possible to confi gure a button for a special function, for example to turn the stairs lights on.
To confi gure the button, perform as follows:
Go to advanced confi guration.
Keep the selected button pressed for 3 s, the door unit emits an acoustic signal to confi rm that the
acquisition has been successfully performed.
PROGRAMMING DATA DELETING
To delete all the data programmed in the advanced confi guration, follow the instructions below:
Go to advanced confi guration.
Keep any button pressed for 5 s at least. The door unit emits a fi rst acoustic signal after 3 s and another
one longer after 2 seconds, to confi rm the deleting.
18
column
interface
ID = n
"B"
Secondary call module with 8 buttons
ID = n
AUX dip 2 = 1
offset = 11
Called users: from 11 to 18
Secondary call module with 11 buttons
ID = n
AUX dip 2 = 0
offset = 0
Called users: from 0 to 10