In any event, it is recommended that this task is carried out by a service technician. In the case of any doubt, please contact your
distributor.
We recommend that this operation is carried out at least once every three months and at the start of every summer.

TANK CLEANING

If required clean the tank, you should empty the water. Clean the inside of the tank with a mild soap solution, rinse and expel the rest with
clean water.
9. OPERATINAL TEST
CHECKS IN TE EVENT OPERATIONAL FAILURE
In some situations, operational failure can arise due to simple causes that users themselves can solve, which is why prior to requesting the
intervention of a specialised technician, we recommend that you carry out the following checks.
The appliance does not work
- Check that it is correctly plugged in.
- Check that electricity reaches the power outlet.
The internal temperature is too high
- Check that there is no heat source nearby.
- Check that the grill is not obstructed.
- Check that the time since the connected equipment until their use is sufficient to cool the liquid.
- Check if the evaporator has ice.
- Check that the condenser is not obstructed.
- Check that the appliance is functioning normally.
In the event of strange or excessive noises
- Check the levelling of the unit as this may cause vibrations.
- Check that there is no object rubbing against any movable element of the refrigerated unit.
NOISE TESTING
- The noise tests were performed in a room without any noise absorption elements and without any large item placed near to the
refrigerated unit.
- The noise levels registered in the acoustic test have been carried out in accordance with the ISO 230 to 235 standards.
Leq (continuous level) is less than 70 dB. (A)
Lp (acoustic pressure level) is less than 130 dB. (C)
NOTE. (A) (C) Frequency weights.
In the event that these checks have not resolved the problem, please contact the customer service desk in your area providing the following
information on the model, serial number and registration shown on the specification plate.
The cleaning of the gas condenser must be carried out with the unit unplugged and removing
the protectors (grills) or taking out the condenser unit (depending on the model)
In order to remove the dirt deposited between the condenser fins, any of the following
procedures are recommended:
Use a toothbrush or soft-bristle brush.
Blow the dirt using a suitable appliance.
Use air pressure to remove the dir.