Press
"set" 1 sec and the set point or set point will appear. Release key.
Up the set point
Press
"up" .Release key.
Lower set point
"down" . Release key.
Press
"a
Once the tank is filled of water, connect the power supply.The thermostat has an on-delay so that there will be launched just when it is
connected the power supply.
Once connected check that the cooler is properly manufactured ice block before proceeding to use. This time can be between 3 and 4 hours
depending on the model and the ambient temperature. The operation limits established for the cooler climate, class N are:
6. RECOMMENDATIONS
The coils liquids must be sanitized every 90 days. This operation must be performed by qualified personnel.
Recycling and disposal of equipment.
7. PRECAUTIONS
The stability of the unit is guaranteed.
Not leave the furniture outdoors
Do not modify the specifications plate or instructions issued by the manufacturer.
Do not touch the unit with wet or damp hands and feet.
Do not touch the unit when barefoot.
Avoid the use of adapters, extension leads or multiple plugs.
Before carrying out any cleaning or maintenance operation, unplug the unit from the electricity supply, first turning off the main
switch and then unplugging the unit.
The unit must not be used by children, persons whose mental, sensory or physical capacities are impaired. Persons who lack
experience or knowledge must be supervised or given instructions for use.
Do not remove the protection from the movable components without having previously disconnected the power supply.
Take necessary precautions before manipulating the condenser unit area, due to the existence of high temperatures of some
of the components and the resultant risk of burns.
8. MAINTENANCE
Before carrying out any cleaning operation, disconnect the unit from the power supply. The good operation and performance of the unit will
largely depend on its correct maintenance, carried out periodically.
The manufacturer is exempt from all liability arising from non-compliance with the procedures contained in this manual.
GAS CONDENSER
The incorrect maintenance and lack of cleaning of the gas condenser of the refrigerated unit can considerably reduce the performance of
the unit as well as shortening the life of the compressor motor. The cleaner the unit, especially the condenser fins, the greater the energy
saving.
Environment
Ambient temperature
Condensation temperature
Relative humidity
In case of be "Tropicalized", the ambient temperature is +43 ° C
Limits
+32 ºC
+54 ºC
60%