Télécharger Imprimer la page

Empire Comfort Systems DVCP36PP30-1 Mode D'emploi page 2

Conversion pour changement de gaz foyer au gaz à ventilation directe

Publicité

Les langues disponibles

Les langues disponibles

Gas input for direct vent fireplace insert converted to
Propane Gas:
DVCP36(PP,SP)30 32,000 Btu per hour
DVCP36(PP,SP)70 32,000 Btu per hour
The direct vent gas fireplace when converted to Propane
Gas will have a manifold pressure approximately 10.0" w.c.
(2.49 kPa) for a maximum input or 4.9" w.c. (1.220 kPa) for
a minimum input at the valve outlet with the inlet pressure
to the valve from a minimum of 11.0" w.c. (2.739 kPa)
for the purpose of input adjustment to a maximum of
13.0" w.c. (3.235 kPa).
INSTRUCTIONS FOR CONVERSION
1. If the fireplace insert is installed, turn OFF gas
and electric supply to fireplace before making gas
conversion.
2. Remove access panel below glass; lift and pull away
from fireplace.
3. Release the two glass frame spring clamps beneath
one of the two glass frames.
4. Remove the glass frame and screen frame as an
assembly.
5. Remove logs from burner assembly.
6. Remove the ten screws around the burner perimeter,
and remove the false floor from the burner assembly.
7. Remove the four screws retaining the burner to the
burner base, and remove burner.
8. Remove Natural Gas main burner orifice from orifice
fitting.
Page 2
9. Install Propane Gas main burner orifice into orifice fitting:
10. Pull upward on pilot hood to remove and gain access
11. Remove Natural Gas pilot injector orifice from pilot
12. Insert Included Propane Gas pilot injector orifice into
13. Re-install pilot hood to pilot assembly. Push downward
14. For DVCP36(PP,SP)30 only, convert gas valve as
15. For DVCP36(PP,SP)70 only, remove Natural Gas valve
16. Adjust air shutter setting to 3/16" open (1/8" with 40 ft.
17. Replace the burner assembly on to the burner base.
18. Replace the false floor to the burner.
19. For vertically vented installations only, replace the flue
20. Replace log set.
21. Replace glass and screen frames, and lower access
22. The converted fireplace must be connected to a supply
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
about our products, please e-mail
us at info@empirecomfort.com.
If you have a service or repair
question, please contact your dealer.
www.empirecomfort.com
• for DVCP36(PP,SP)30, Orifice is MARKED #51
• for DVCP36(PP,SP)70, Orifice is MARKED #51
to pilot injector orifice.
burner with 5/32" hex (Allen) wrench.
pilot burner using a 5/32" hex wrench.
to snap in place.
instructed in S.I.T. Propane Gas Valve Conversion Kit.
from manifold pipe and replace with included Propane
Gas valve.
vertical vent).
restrictor with included Propane Gas flue restrictor.
panel.
of the conversion gas and checked for leaks at all
connections.