NOTE: Be sure electricity is turned off at the main power box
NOTE:
before wiring.
b. Connecting the wires from the wall switch to the wires
from the wall outlet box. (Fig. 3 & 4)
1
Connect the black wire from the switch to the black
wire from the wall outlet box.
2
Connect second black wire from switch to the black
wire from the wall outlet box feeding to fan installation.
3
Connect the yellow/green striped wire form the
switch to the ground terminal on the wall outlet box.
NOTE:
NOTE: If your outlet box has a ground wire (green or bare
c o p p e r ) c o n n e c t t h e w a l l c o n t r o l ' s g r o u n d w i r e t o i t ;
otherwise connect the wall control's ground wire directly to
one of the screws from the outlet box.
Carefully tuck the wire connections inside the junction
4
box. Secure the wall switch with the two screws
provided. (Fig. 4)
5
Attach the wall plate over the wall switch and secure
with the two screws provided. (Fig. 4)
SUPPLY CIRCUIT
BLACK
4
3
2
1
BLACK
Fig. 3
Switch
Screws
Wall Plate
Screws
4
3
2
1
Fig. 4
©2019 Hinkley Lighting, Inc. | hinkley.com |
Ground
Conductor
Outlet Box
Green Ground
Lead
Ground to
Fan
Outlet Box
09