Fdnet-Specific Aspects; Example For The Use Of The Video Fire Controller Fdv241 - Siemens FDV241 Manuel De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Description of the device
7.3

FDnet-specific aspects

7.3.1

Example for the use of the Video Fire Controller FDV241

16
Building Technologies
Fire Safety & Security Products
All manuals and user guides at all-guides.com
The Video Fire Controller offers the following FDnet-specific features:
Communication via FDnet (detector line)
Integrated line separator
Communication with the fire control panel takes place over the detector line. The
Video Fire Controller is configured from the fire control panel.
The Video Fire Controller requires auxiliary power supply.
Basic functions of the Video Fire Controller
Trigger recordings with pre-event and post-event recording from the fire control
panel via the FDnet.
Start/stop recording directly from the fire control panel via the FDnet.
Report tampering of the Video Fire Controller to the fire control panel.
The alarm message is generated, for instance, when the video signal of the
camera is interrupted.
Status inputs
The inputs of the Video Fire Controller are status input, which will trigger a change
of state as soon as they are activated.
Monitoring of the video functionality
In case of a malfunction of the Video Fire Controller, an error message will be sent
to the fire control panel. See Section 13: Trouble shooting.
Fig. 3
Example of use
The Video Fire Controller is connected to a camera and to the FDnet. See Section
9.4: Connecting the Video Fire Controller FDV241 to the FDnet. When an alarm is
triggered via a peripheral device (e.g. manual call point), a message is sent to the
FC20xx
FC20xx
Fire
Fire
Fire Brigade
Fire Brigade
Total : 02
Total : 02
Alarm
Alarm
in 04 : 59 min .
in 04 : 59 min .
+ Zone : 123 Addr :
+ Zone : 123 Addr :
04 Autom . Fire Alarm
04 Autom . Fire Alarm
Entrance Hall /
Entrance Hall /
Reception
Reception
01
01
ALARM
ALARM
+ Zone : 456 Addr :
+ Zone : 456 Addr :
02 Fire Alarm
02 Fire Alarm
2 nd Floor / Room 202
2 nd Floor / Room 202
02
02
Intervention
Intervention
Show
Show
Text
Text
Details
Details
Us er 1
Us er 1
Us er 2
Us er 2
Opt ional
Opt ional
Us er 3
Us er 3
Acknowledge
Acknowledge
Us er 4
Us er 4
More Alarms
More Alarms
Res et
Res et
FAULT
FAULT
Remote alarm
Remote alarm
Alarm delay Off
Alarm delay Off
Active
Active
ISOLATION
ISOLATION
Fault / Off
Fault / Off
Premises / Manned
Premises / Manned
Alarm Device
Alarm Device
TEST
TEST
Act ive
Act ive
Fault / Off
Fault / Off
Control
Control
User 5
User 5
System
System
On -
On -
Act ive
Act ive
User 6
User 6
Fault -
Fault -
Fault / Off
Fault / Off
Sint eso TM
Sint eso TM
Fire control
panel
11.2008

Publicité

Table des Matières
loading

Table des Matières