Castel XELLIP XEK-AUDIO-1B Fiche Technique page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AUDIO VIDEO IP KIT
Configuring relations
The Web server is where automatic controls, also called relations, are configured
There are two types of relations:
Time: used to trigger actions at identified time slots. There are three levels of priority for a time relation (high,
medium and low).
Logical:
↘ Logical condition: used to trigger actions at certain status conditions (active, inactive, etc.). A logical
relation can integrate several conditions by operators such as AND, OR, NOT, XOR. Likewise, a logical
relation can trigger several actions.
↘ Digital condition (Counting): used to perform actions by comparing the value of a counter with different
thresholds. It is also possible to add or subtract counter values and compare the result obtained.
Configuration of web server users (software users)
The Web server for the kit can grant, modify or remove rights for users by specifying their login, password and
operating language.
Profile configuration
Kit operating profiles can be created, or modified or deleted. Each profile specifies a kit priority, a configuration of
function buttons and access rights to the kit.
The kit can operate with a unique profile or with different profiles according to time slots.
SNMP administration management
The kit features an SNMP agent (Simple Network Management Protocol) that can respond to SNMP requests and
send notifications (TRAPS) to an SNMP manager.
From web pages, it is possible to:
Configure different communities (read/write)
Configure system data (sysContact and sysLocation)
Configure notifications (recipient, community, etc.)
Download MIB Castel
It supports the SNMPv1 and SNMPv2c versions.
Self-test function
The kit has several tests to validate its operation:
HP/MIC self-test: can remotely test the right operation of the speaker and microphone. From the 'advanced
parameters' page, the levels of this test can be adapted according to the installation environment. This test
can be activated from the web server or by an SNMP command. The result of the test can be viewed from the
web server history and by an SNMP notification.
Mechanical button self-test: the detection of a locked mechanical button (contact made for more than 20 s) is
signalled by an SNMP notification and an event is signalled in the web server history.
Backup and recovery of system parameters
A full backup or recovery of the kit parameters can be made (configuration, profiles, relations, directory, etc.
The kit can be reset to factory configuration by pressing the reset button for 10 seconds when the kit is started up.
Station update
For the update, you will be provided with a file containing the new software version, if necessary.
You must then download this file via the Web Page. The entry station will restart so as to apply the update. The
update does not modify the user parameters in any way.
Backup on power outage
When a power outage occurs, the kit can back up the following information:
counter values
history
backed up events (these events are defined from CastelServer)
The interface statuses
History function
The history displays the events that occur on the kit. They are listed by showing the date and time of the relevant
event, a description and additional information.
Technical data sheet no. EN-604-0092C
www.castel.fr
FR
EN
Page 18 / 20

Publicité

Table des Matières
loading

Table des Matières