I Setting the Fan Speed
• Press 4 to select:
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 to select:
AUTO
For COOL/DRY operation.
AUTO
Swing up/down automatically.
For HEAT operation
AUTO
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows in a horizontal
direction. As the temperature rises, the
hot air blows in a downwards direction.
I Setting the Horizontal Airflow Direction
• Press 6 to select:-
Indoor
Horizontal
Unit
Airflow
Direction
Remote
AUTO
Control
For COOL/DRY operation.
AUTO
Swing left/right automatically.
For HEAT operation
AUTO
When the discharge air temperature is
low, there is no air swing. When the
temperature rises, the horizontal airflow
louvers swing left/right automatically.
G Use this air conditioner under the following
conditions:
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
32
23
(Maximum Temperature-Heating)
(30)
(-)
Minimum Temperature-Cooling
16
11
(Minimum Temperature-Heating)
(16)
(-)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has
been turned off with the remote control.
If operation is stopped, then restarted immediately,
the unit will resume operation after 3 minutes.
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preferred cooling
comfort level.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
(Unit in °C)
falls, the heating capacity of the unit might be
Outdoor
reduced.
Defrosting Operation.
DBT
WBT
Depending on the outdoor temperature, the operation
43
26
occasionally stops to melt the frost on the outdoor
(24)
(18)
unit.
16
11
(-5)
(-6)