To Restart Heater - Homelite HHC35A Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

100577
4. Plug heater's power cord into approved, grounded, three-wire extension cord.
Extension cord must be at least six feet (1.8 meters) long.
Extension Cord Size Requirement
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm
11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm
5. Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet.
Heater will start when extension cord is plugged into outlet. If not, push in
heater's flame-out control reset button (see Figures 6 and 7).
Flame-Out
Control
Reset
Button
Figure 6 - Flame-Out Control Reset Button, 35 Model
Flame-Out
Control
Reset
Button
Figure 7 - Flame-Out Control Reset Button, 100/150 Models
To Stop Heater
1. Unplug extension cord from outlet.

To Restart Heater

1. Wait two minutes after stopping heater.
2. Repeat steps under "To Start Heater".
2
) rated cord
2
) rated cord
2
) rated cord
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hhc100aHhc150a

Table des Matières